Jump to content

Search the Community

Showing results for tags 'error1172'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Software & Hardware Discussions
    • LabVIEW Community Edition
    • LabVIEW General
    • LabVIEW (By Category)
    • Hardware
  • Resources
    • LabVIEW Getting Started
    • GCentral
    • Code Repository (Certified)
    • LAVA Code on LabVIEW Tools Network
    • Code In-Development
    • OpenG
  • Community
    • LAVA Lounge
    • LabVIEW Feedback for NI
    • LabVIEW Ecosystem
  • LAVA Site Related
    • Site Feedback & Support
    • Wiki Help

Categories

  • *Uncertified*
  • LabVIEW Tools Network Certified
  • LabVIEW API
    • VI Scripting
    • JKI Right-Click Framework Plugins
    • Quick Drop Plugins
    • XNodes
  • General
  • User Interface
    • X-Controls
  • LabVIEW IDE
    • Custom Probes
  • LabVIEW OOP
  • Database & File IO
  • Machine Vision & Imaging
  • Remote Control, Monitoring and the Internet
  • Hardware

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Personal Website


Company Website


Twitter Name


LinkedIn Profile


Location


Interests

Found 1 result

  1. Hi All, I'm trying to automate the CSI-2 (MIPI D-PHY Compliance Test Application) provided along with the Keysight DSOS404A Infiniium S-Series DSO using LabVIEW. The "Automated DigitalTest App Remote Toolkit" provided by Keysight comes along with an LV project, with a test VI. Steps followed so far... Installed LV 2014 (14.0f1) 64-bit & activated on Windows 7 Pro SP1 64-bit on a NI PXIe-8135 - works fine Installed Keysight Infiniium Scope Application Software & activated the license - works fine Installed IVI drivers compatibile with the Keysight DSOS404A from Keysight website Launched Main Interface VI from inside the project "Example Labview Remote Client" - works fine Filled the correct IP of the Scope & clicked Connect - Connected message popped up Clicked the Refresh Test List button and observed that the list of Available Tests is loaded properly - works fine Select some tests from the list of Available Tests & clicked Run - works fine Clicked the Disconnect button - Disconnected message popped up VI got stopped Now, I clicked the Run button of the VI, and it started throwing .Net error "Object reference not set to an instance of an object" 2 times, and finally threw "Error 1172 occurred at Invoke Node". From now on, the VI wouldn't run properly. Sometimes, closing LV & reopening the VI again is the ONLY way it works properly without throwing the .Net error 1172. Sometimes, waiting for longer time before running the VI is the ONLY way it works without throwing the .Net error 1172. Any help would be highly appreciated, as I'm dumbstruck without having any clue why this behaves so weirdly so far.
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.