About This File
This JKI RCF Plugin sets the Visible Frame property of a Case Structure while the owning VI is running. Use it to follow the execution through the cases in your string-based State Machine/Sequencer when Execution Highlighting isn't fast enough (and, it's never fast enough).
The use-case I wrote this to improve is setting a Breakpoint on the Error wire coming out of the main Case Structure and probing the Case Selector terminal so I can float-probe wires during execution. The problem with this is that I had to manually select the current frame every time. This is boring, so I developed this plugin to automatically set the Visible Frame to the case most recently executed.
Use - Select the String wire connected to the main Case Structure's selector terminal, invoke the JKI RCF and select StateFollower.
Special thanks to - AristosQueue, for his help over here.
LabVIEW versions - tested in 2009 & 2011 - it should work in 2010 as well
Installation - use VIPM to install the VI Package
License - Creative Commons 3.0 Attribution (Really, do whatever you want. I don't care.)
What's New in Version 1.2.0
Released
- released in LabVIEW 2009