  1. Hey all, I am supposed to customize the Test Stand test report, I just looked the test stand help manual, which shows very simple example of how to add some additional Rows and Columns in the Table. But my task is to entirely change the Table structure and appearance and to include some other additional description of the test procedures into the table. So I planned to add this additional stuffs into the original xml document and to edit the style sheet to get the appearance. But the thing is I am very new to the xml, XTLS, Javascript, VBScript and the HTML, unfortunately the Style sheet was developed with the four scripts all together. I can't able to find the perfect documentation of the Style sheets also, studying these scripts and implementing to get the desired table stucture will take a lot of time. Is there any other way to do this ?????? Thanks, AshwiN
  2. Thanks for your reply Bruce. I also created a new project but useless, the same problem persists. I will try the final option of contacting the National instruments........ Thanks AshwiN
  3. Sorry Bruce, I can't post that VI. It's a licence kind of thing. I am also new to LV 8.2, the labview crashes meaning it just disappears with no pop message after clicking the Main VI or during building the MainVI. As I told earlier, the VI is opening and running before building the Main VI as a exe, while building the whole LV gets disppear and afterwards the Main VI is also not opening. AshwiN
  4. Once the VI gets stuck, even if I replace the Main VI with the backup, the new Main VI is also not opening. If I use that Main VI in some other new VI as a sub VI, that thing is also not working resulting in the LV crash. I have to delete the entire Folder and replace with the back up folder. I tried it several times and after that the "Generate Preview" is not showing errors but the VI is not building, once I click the build option LV closes and the same thing is repeating. Its taking a hell of time. AshwiN
  5. I am supposed to build an ExE and Installer for a simple LV program, a task of 15 min. The program was done on LV 8.2, the main VI is not showing any errors and the mass compile also worked perfectly. But the application is not building and in the Generate Preview it is showing some errors. I closed the entire LV program and tried to reopen the Main VI file, it is not opening and the LabVIEW closes. The problem seems to be ridiculous and I spent nearly 2hrs, still I can't able to figure it out. Any Idea???? AshwiN
  6. Bored in the Heaven, just Rocking in the Hell

  7. I don't think TCP/IP is a better option for C# Connectivity, just create a DLL from your C# code and use ' Constructor ' to load that DLL which is found in Fuctions >> Connectivity >> .Net palette in the LabVIEW. Afterwards you can use the Propery and Invoke nodes to call the methods present in the DLL. Ashwin
×
×