  1. Smithd, I really appreciate the help. It will take me a while to sift through everything. I've spent most of the day so far looking into the OPC UA solution. The daq.io product looks great for remote access to data, but i'm looking more for local access right now. The influxdata products look like they are powerful. I'm not sure how they would interface with labview yet. Thanks again.
  2. Thank you smithd. I have explored the dcaf option in the past. Ultimately, it looked like porting our LOOP system over to dcaf would create a system too hard to manage. The OPC UA option is appealing because the OPC server could also handle the modbus communication. I wasn't aware that there were third party apps that could log the data and then access it through labview APIs. I will definitely look into it. However, it seems like the licensing could still be an issue, especially if we would have to buy a OPC UA license and a DSC runtime license for each deployment. I'm still looking at your RTI DDS suggestion but I don't think I have enough of a grasp on it to understand if it's a viable solution.
  3. Hi, My company has a software/hardware product which is deployed as a labview executable. The software is of the SCADA type and it typically monitors and controls 5-20 machines using modbus. We also log data from each machine (every ten minutes, 10-20 data points per machine). The gui allows the operator to trend data in 24 hour increments by selecting the machines and day of the year. We have been using DSC and Citadel to store the data as traces which allows us to locate the data with a start and stop time for display. However, my company is not happy about the licensing of DSC and has asked me to look into other options. Part of the issue with DSC is that although it is supported by NI, it is no longer being developed, fixed or improved. An example of this is the DSC modbus IO servers which map to shared variables. There are known issues with how certain write functions are implemented which make it impossible to write to many modbus devices. NI has acknowledged the problem but is not going to fix it. So we have developed our own modbus routines, making use of the NI modbus library. On the data logging and trending side, I would like to know if there are reasonable alternatives within the labview environment that don't require a DSC license on each deployed machine? I know that citadel uses TDMS and it seems like a great format, but I'm not sure if it would be too much work to build out code for logging and retrieving time series data using the low level functions that labview provides. As you can probably tell, i'm familiar with labview but don't have a lot of background in databases and data management. Does anyone have experience trying something similar? Thanks
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.