I am using WFdebug then getting data from that device. After debug the values come as follows
Channel 01 Converting RTD sensor InBuff= 476.449 Converted hex value to AD420 = FFC5
Channel 02 Converting RTD sensor InBuff= -1809.400 Converted hex value to AD420 = 5BEF
Channel 03 Converting RTD sensor InBuff= -1809.400 Converted hex value to AD420 = 5BEF
Channel 04 Converting RTD sensor InBuff= -1809.400 Converted hex value to AD420 = 5BEF
Channel 05 Converting pH sensor InBuff= 0.000 Converted hex value to AD420 = 0000
Channel 06 Converting pH sensor InBuff= 0.000 Converted hex value to AD420 = 0000
Channel 07 Converting pH sensor InBuff= 0.000 Converted hex value to AD420 = 0000
Channel 08 Converting pH sensor InBuff= 1.813 Converted hex value to AD420 = 2126 [8A
Channel 01 Converting RTD sensor InBuff= 476.499 Converted hex value to AD420 = FFC5
so on.
After I connect it with Write to Delimited Spreadsheet following message come up These cannot be wired together because their data types (numeric, string, array, cluster, etc.) do not match. Show the Context Help window to see what data type is required.
The type of the source is double [64-bit real (~15 digit precision)].
The type of the sink is 1D array of
double [64-bit real (~15 digit precision)].
Thanks