0

Reputation

  1. Finally, I was able to solve the problem. I do not know which of the two steps led to success: I renamed in folder C:\Users\Public\Documents\National Instruments\NI-IMAQdx\Data\XML the file avt_E0020006_1.44.xml. I copied the content of the folder PreProcessedCache from an IMAQdx 14.0 PC to the target PC. Now NI-Max can open the cameras. The XML file has been recreated.
  2. I try to migrate from LV2014 to LV2020. If I try to open Allied Vision Manta_G 145B camera in NI-MAX i get Error 0xBFF6901D "unable to load xml file". IMAQdx Version is 20.6 (RT + Dev). Basler Cameras work fine. I have upgrated the firmware of the cam to the newest version, but it didn't help. I have also installed IMAQdx 21.0, but without success. A Manta-032B works without problems... Any help or workaround is most welcome. Is there any way to load the XML file manually?
×
×