Matheus
Members-
Posts
11 -
Joined
-
Last visited
Never
Matheus's Achievements
Newbie (1/14)
0
Reputation
-
QUOTE(Michael_Aivaliotis @ Oct 13 2007, 09:31 PM) [ Hello! I am brazilian, place of beatiful girls, with BIGs party (like the carnaval), big Universities, Soccer Country! If anybody unknow this paradise, will be well come! I work with labVIEW since 1997 with 5.01 version, I worked with energy generator aquisition, factory of RF boards, etc... I am a System's Analist, and MASTER student. Today I work with a Air Planes Factory using the LV 8.2.1. We use several kind of data aquisition, like a cFP, PXI, SCXI, MTS, MOOG, PCMCIA, PCI, etc.. My pleasure!!!
-
QUOTE(Neville D @ Oct 15 2007, 03:32 PM) Thanks for your atention, It's true, the rate of TC Modules are more slow than AI aq. http://www.ni.com/pdf/manuals/372056a.pdf But I can't understand this manual, it says: " The all-channel sample rate of the cFP-AI-118 is 10.42 kHz with no filtering. If you enable filtering on any channel, the all-channel sample rate is 3.45 kHz." I am already using separately loops to read AI and TC signal. In NI forum, i found another people with the same problem, i called to NI Support in Brazil, but they unknow this problem! BUT, in any event, THANKS A LOT. IF ANY BODY CAN HELP ME..... I WILL BE ETERNALLY GRATEFUL.
-
Hello, I've never used Property Node for this case! I usually use... below.... http://forums.lavag.org/index.php?act=attach&type=post&id=6343 You must be careful with the while loop, try to use WHILE TIMED LOOP sometimes, can be a good way. Good Luck...
-
Hi, Thanks My LV version was 8.20 full development too, but we acquired Professional upgrade with FieldPoint and others toolkits. In this locate-> C:\Program Files\National Instruments\Shared\License Manager\Licenses I found -> LabVIEW_AppBuilder_PKG_080200 Then, I think that updade already was made. Please, how the best or the correcty mode to do that (create a .EXE application) I was create a Project, build especifications, and...... nothing is happen.... Is there any more that I am forgetting?
-
Hello... I agree fully, but to change more easy, use the TAB constant as delimiter, this is more used when we import a TEXT using EXCEL. %.;%.5f -> float number with five significant digits using coma. good luck! QUOTE(crelf @ Jul 6 2007, 09:33 AM)
-
Hello, It's my first post, I'm Brazilian and I work with airplanes constructions. Qualification and Development Tests Laboratory. I work with LabVIEW since 1996, versions 5.01, 7.1 and I'm going to start to work with LabVIEW 8.20 professional. Well..... I need to generate an application (.exe) with our great friend APPLICATION BUILDER, at this point, I can't to do this. I know that exists some llb that a can import named APP*.*, I think that ones are my APPBuilder. Butttt, I don't obtain!!! I'm waiting for suggestions. Thanks and best regards.