  1. Dear LogMan, That's the solution! Many thanks! Now everything is working fine 🙂 Hannes
  2. Hello hooovahh, I know, that this is a crosspost. But as I didn't get a solution there, I try it in this forum. Maybe an expert in this forum can help me. Hannes
  3. Hello I am trying to connect network streams from two different application to one other application. Application A <> Application C Application B <> Application C I have created three test projects showing the problem. In this example I try to connect from Application A to Application B and from Application B to Application C. It is working without problems, as long as the applications are running in the LV development environment. As soon as I execute the executables, only one application can connect, the other gets the error -314350. (From https://labviewwiki.org/wiki/LabVIEW_Error_Code_Family: LabVIEW: (Hex 0xFFFB3412) Another application is already streaming data to an endpoint in the context you specified. If you specified a context name in the reader name or writer name terminal of the endpoint, you must specify an unused context name. If you did not specify a context name, you must specify an unused context name by entering an endpoint URL in the reader name or writer name terminal.) The following urls are used: The url in Application A is //localhost:ScriptHandler/script1_out_writer (if in executable) The url in Application B is //localhost:ScriptHandler/script2_out_writer (if in executable) Can anybody help me to solve this issue? Regards, Hannes NetWorkStream.zip
×
×