  1. Hello, I want to create an unsteady pulse width modulated signal to control solenoid valves. I can create steady pwm signals. For example i want to create a pulse signal with a frequency of 1 hz (this is not the frequency of the pwm signal of the solenoid valve, it is 400 hz). I mean the valve will run 0.4 seconds with a duty cycle of 0.9 and 0.6 seconds with a duty cycle of 0.2. As the same example i will create a sinusoidal duty cycle for example with a frequency of 2 hz. If i can solve the pulse problem i can do the rest. Can anyone help me?
  2. i am making multiple channel measurement using daq asistant. i want to take separately the data of each channel. in index array function it doesn't exist a 'disable indexing' selection in LV 8.2.1. or i couldn't find it. how can i take one row from a 2 or 3-row array?
  3. QUOTE(Tim_S @ Jan 26 2008, 05:44 PM) thank you for the help.
  4. i mean if i take signal for 5 seconds, i want to get 500 values. but i get last 100 sample values. for the time, i wnt to get the exact time for each sample value.
  5. i'm getting thermocouple data from a NI board. but also i want to get exact time like hh:mm:ss and also miliseconds. because i get 100 samples per second. how can i do that? also why my task gets last 100 data?
  6. i use MAX to get data. but i want to make my own GUI using LV. but i have problems about configuring the Vİ's in LV. it does not occur a data acquisiton palette in LV. i have installed ni-daqmx. when i use 'traditional ni-daq to ni-daqmx converter in MAX, is gives a warning like: 'this module's chassis currently exists in your ni-daq mx configuration. if you mark this module for conversion, then the existing chassis and its modules will be removed from your ni-daq mx configuration before converting this module.' am i doing the right thing? if i convert them, can i still use MAX to get data? and will this conversion solve my LV problem?
  7. i use MAX to get data. but i want to make my own GUI using LV. but i have problems about configuring the Vİ's in LV. it does not occur a data acquisiton palette in LV. i have installed ni-daqmx. when i use 'traditional ni-daq to ni-daqmx converter in MAX, is gives a warning like: 'this module's chassis currently exists in your ni-daq mx configuration. if you mark this module for conversion, then the existing chassis and its modules will be removed from your ni-daq mx configuration before converting this module.' am i doing the right thing? if i convert them, can i still use MAX to get data?
  8. I've been using LV 6.1 Full Development System. Now I'm tring to get signals using NI boards. But I don't have data acquisition (i mean in the functions menu there is not a data acquisiton sub-menu). If I upgrade to LV 8.2, will I have data acquisition?
×
×