I have an AIT MIL-STD-1553 PXI card, and I am trying to control it using LabVIEW. The card shows up in MAX, and a Test Panel is able to communicate with it, as shown in the attached images. Further, if I open a VISA session with the instrument, it seems to be okay. (I have only tried doing a VISA Open and VISA Close, resulting in no error. Since I don't know any other VISA commands to this instrument, and since it does not seem to speak SCPI, I have been limited to simply opening and closing the VISA session.) However, when I try to do a simple Initialize using the AIT LabVIEW vis, I get an error code -1, stating that there is "No Hardware Found". This simple vi is shown in the other attachment. I have also tried different "network path in", and "board index in" values, without success. Any time I change the network path in to anything but "local", I get an error code -5, stating that "Remote network connection not supported by this hardware". I have verified that the latest AIT firmware is loaded on the card. I'm running the AIT LabVIEW vilib components, and LabVIEW 2015. Any help would be greatly appreciated. Thanks. Dan