Jump to content

Search the Community

Showing results for tags 'root loop'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Software & Hardware Discussions
    • LabVIEW Community Edition
    • LabVIEW General
    • LabVIEW (By Category)
    • Hardware
  • Resources
    • LabVIEW Getting Started
    • GCentral
    • Code Repository (Certified)
    • LAVA Code on LabVIEW Tools Network
    • Code In-Development
    • OpenG
  • Community
    • LAVA Lounge
    • LabVIEW Feedback for NI
    • LabVIEW Ecosystem
  • LAVA Site Related
    • Site Feedback & Support
    • Wiki Help

Categories

  • *Uncertified*
  • LabVIEW Tools Network Certified
  • LabVIEW API
    • VI Scripting
    • JKI Right-Click Framework Plugins
    • Quick Drop Plugins
    • XNodes
  • General
  • User Interface
    • X-Controls
  • LabVIEW IDE
    • Custom Probes
  • LabVIEW OOP
  • Database & File IO
  • Machine Vision & Imaging
  • Remote Control, Monitoring and the Internet
  • Hardware

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Personal Website


Company Website


Twitter Name


LinkedIn Profile


Location


Interests

Found 1 result

  1. I have been working on an architecture that uses VI Server to send messages between application instances, both local and across the network. One of the problems I have run into is the fact that VI Server calls are blocked by activity in the root loop (sometimes referred to as the UI Thread). There are several things that can cause this: other VI server calls, system dialogs (calls to the one and two button dialog functions), if the user drops down a menu but does not make a selection... (I'm sure there are more...) Since this is a pretty normal way of communicating between applications, I was wondering if anyone had any ideas for a work around. Here is a basic description of my architecture: Message is created and sent to local VI that sends to outside application instance. Local sending VI opens VI server connection to remote instance. It then calls a VI in the remote instance that takes the message as input. This remote VI them places the message in the appropriate queue on the remote instance so it gets handled. If the remote instance root loop is blocked, the sending VI on the local machine is also blocked. I could try to eliminate all system dialogs from the remote application, but that only partially addresses the issue. I really wish a future version of LabVIEW would eliminate this problem with the root loop and VI Server all together. BTW: using LV2012 but this issue exists in all versions. -John
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.