  1. Hi Sunayana, In the LabVIEW example finder there is a counter example. It is called "Edge Counter.lvproj" Frequency would be the number of counted edges per unit of time. The example should provide a starting point. However, you will still need to convert the analog signal to digital using some sort of crossing detector. Hard to say how to do this without knowing your resources. Kind regards, Rick Wagner
  2. How are the TCP/IP addresses of the instruments assigned?
  3. Hi Scott, The TCP/IP protocol has packet size limitations that are enforced by routers and other equipment on the network. Your setup indicates that there is no other equipment that is in place. However, I would check that the MTU and RWIN settings of the the machines are not the problem. The settings often cause problems with large data packets. You can use DrTCP021.exe to view and set these settings on a 2000/XP machine. The fact that you reduced your data payload size to make the connection work would indicate that the settings may be an issue. Regards, Rick
×
×