  1. I'm running Windows 10 and Labview 2014 sp1. For some reason now I cannot do an ALT-TAB to look at my diagram while I'm running a program. The screen comes up but it will not allow me to select it. Did I miss something in Labview? Thanks.
  2. I have a PXI that hosts a shared variables library and a PC running a user interface program. Through the NI Distributed System Manager I can see the shared variables update but the PXI only updates the variables back to the PC if the PXI program is running on a development computer. Simply put, PXI address is 169.254.1.100, interface PC address is 169.254.1.105, development computer is 169.254.1.108. On the PC I enter Width and Height, the PXI calculates Area which is then displayed on the PC. If the PXI program is NOT running on the development computer, I see the Width and Height values update but not the Area. I've tried messing around with the aliases files, building the project different ways and have read every white paper available on NI. Totally stumped, I didn't think this was that difficult to do. Using Labview 8.6 RT (no DSC module), both PC's are WinXP. Any help would be appreciated.
  3. Not sure if this is the correct forum area for this question...I usually use an Automation Direct CMore HMI to interface with my PXI systems using Modicon Modbus TCP/IP. On a new project, my customer suddenly decided that they need to use a keyboard and mouse instead of a touchscreen and they want at least a 19" monitor. The CMore is only available in 15" and you cannot use a keyboard and mouse. I found one 19" HMI from Beijer Electronics, with a $5500 price tag and of course, new design software to be learned. If anybody out there has any experience with large HMI's that can be interfaced with a PXI, I'd greatly appreciate a lead. Thanks.
  4. I have it installed on my laptop so I can keep working on it at home but there is an issue that I'm currently working with NI on...MAX will not function correctly on the laptop even though it does on another identical one. Very frustrating. I was on the phone with tech support last Friday for 4.5 hours to no avail. I need it to work because I can't haul my desktop with me when I travel to load updates on my realtime PXI systems. I decided to clean up my old code first and then start manipulating it. Worst case scenario, I know the old code works fine. This is probably the best project to experiment with because it's not hot right now and it's not overly complex. The "Manual" part of the machine is pretty simple but the "Testing" mode is going to be a little trickier (data storage, graphing, recalling data for comparison, etc). Thanks again for all your help!
  5. Thank you MikaelH and Daklu...I will be looking at the links in a bit. I will be using the bulk of my existing program since I know it works on 3 other machines but I am embarrassed by it! Daklu, I have no idea why the two parallel loops inside of another main loop, I believe I had an issue with both stopping at one point. Probably overkill. 99.99% of my customers never see my code but one time I had a customer basically hand my a$$ to me over how bad my coding style was! He had been afforded the luxury of taking every available class from NI and worked at a very large company where he basically had time to try out stuff. I'm the only software engineer in a 5 person company so things are a little tighter! Thanks again and I'll probably bug you both at some point with hopefully simple questions. I've never worked with classes so this will be a new venture.
  6. I have written many, many programs in LV but I'm sorry to say that I have not kept up with upgrading my coding skills. The last few years I've only written very simple programs that didn't have to do too much. We are a very small company that has really been struggling so taking a training class is not on the menu but I'm having a hard time finding examples, the examples I find are so simple. My problem is how to go about selecting a design pattern. I am upgrading/enhancing a program that I wrote over 10 years ago and obviously want to use good techniques. I understand all the concepts but start to get overwhelmed when I start using one technique and figure out things that won't work, start over with a different idea, won't work...etc. In the old program (don't kill me) I basically used a 3-stage sequence (initialize, main, destroy) with the main consisting of two parallel while loops inside a while loop, one to do stuff every 10ms and the other to capture user events. I know, I know, I can see eyes rolling. I won't get into the excessive amount of local variables used... Very simply put, I want to do the exact same thing but better...read/write digital, read/write analog (user changes the analog control), user presses buttons to open/close valves, store data, and of course update my display values every 250 ms. Since I have an actual project to work on (finally) I want to do it correctly. I've decided to start with a producer/consumer format and build from there. Comments? Suggestions? I'm hopefully getting a few more projects soon and hopping back onto the LV train. Thanks.
  7. task

    canexpert error

    I cannot install any NI-CAN drivers on my Dell Vostro 1510 laptop. I've done numerous uninstall/reinstall procedures to no avail. The desktop I use for development works fine, all identical software was installed on both machines in the same order. I can install the XNET drivers but cannot include anything relating to CAN, even older drivers. What happens is that when I click on the + in front of software, nothing shows up, and no remote systems are displayed (I have a PXI attached). The PXI shows up fine on the desktop. My newer benches have the latest XNET PXI card installed but the older ones (old by 8 months) still have the CAN card. I need to be able to connect to the older ones to make changes and do not want to lug the desktop around. All the MAX drivers are the latest and I'm using Labview 8.6 RT. Any suggestions? I have run Dependency Walker on both machines if anybody wants to see the results. Thanks for any clues.
  8. Found it...looking through the NI site I found a blurb regarding software updates being installed after drivers. Exactly what happened. Apparently the DAQmx drivers were updated 6/18 and Labview 8.5.1 upgrade was installed on 6/20. Since the drivers were the exact same ones, they were not updated. Uninstalled all, reinstalled and problem disappeared.
  9. There are still problems!!! Everything works fine as long as I run the code from the host computer. As soon as I dump it into the RT module, none of the digital works. From what I understand, this happened before on one of the previous machines (I'm working on # 4 of 4). Our local NI rep was in, did nothing, the previous programmer played around with it, and things started working. Well, they don't now. The only difference, and this may have something to do with it, it's a different processor (PXI-8184), same model but physically a different one. We had a hard drive fail in the field (temperature) and had to replace it. After jumping through hoops to get that to work, I fired everything else up (no changes to the software) and started encountering this problem. I have a request in at NI for assistance. We'll see how that goes... To summarize my problem: Everything works fine while running from the host computer (all my DAQmx tasks function properly)...as soon as I dump it to the RT module to run as start-up...no digital. I've even swapped slots to make sure that wasn't an issue. I'm going to try and write something very, very simple to prove it all out but I've basically done that by disabling everything unrelated to the DAQmx stuff. Thanks.
  10. The problem has been resolved. It was an initialization error. The default case would wipe out the task. Two other people (newbees) worked on this before me so I have a lot of clean up to do! Too many unnecessary variables, cases, etc. Thanks for the reply.
  11. Problem Description : Hardware: PXI-8184 (chassis PXI-1042), PXI-6221 (slot 2 in chassis) Software: LV RT 8.5.1, DAQmx 8.7.1 (see MAX.jpg), Windows XP Problem: Task does not function within program (CounterRead.jpg). I can run the task within MAX (MAX.jpg) while the program is running and I can see the counts. All other tasks work fine. I have eliminated everything else in my program except this task and it still doesn't function and I do not get any errors. I hate to upgrade any of the drivers, if they're available, because I have several other units out in the field with the same configuration. I recently inherited this project. I've tried different types for the task (raw, Counter Dbl 1Samp, etc). Thanks.
  12. task

    Modbus in RT

    QUOTE(David Wisti @ Feb 1 2008, 04:41 PM) Resolved...I had to change the address of the "PLC" in the CMore. It was set to the PC and not the PXI. I put the ModbusSlave under the variables in the RT area (as I mentioned earlier). Now the PXI and CMore are communicating. Now I just have to adapt all the code I previously wrote under the PC for the RT system. Thanks for all the input.
  13. task

    Modbus in RT

    QUOTE(ned @ Feb 1 2008, 04:05 PM) The addresses are correct and I'm using them the correct way...everything worked fine when I was running the program under My Computer and not the Real Time Controller. I guess this is part of the learning curve on how to use the RT stuff. I moved the modbus stuff into the variables-network-RT(separate).lvlib and the "cycle error" went away but I am still unable to read/write anything. I'm doing what I think is logical and I'm probably missing something huge! I'll keep plugging away...
  14. task

    Modbus in RT

    Hi, I'm a long time labview user but new to using a PXI controller and RT module. Here's my dilemma... The PXI (PXI-8184) will be connected to a Automation Direct CMore touchpanel via modbus ethernet. No host PC will be present in the end. I have the PC and the CMore talking via modbus (CMore is the master, PC is the slave). All this works fine. Now I'm trying to write the actual RT code that will eventually run on the PXI controller. My problem is getting the modbus stuff to work. All the IP addresses and subnet masks are set up correctly. Under my PXI system I set up a ModbusSlave I/O server. It took awhile but I figured out how to set up the shared variables. I tried several different methods but it still doesn't work. Example: Variable 00001, bind to source ModbusSlave0001, boolean, network published. Is this the direction I should be going or am I off base? I get a deployment error: Cycle detected (addresses of the boolean). I just need a nudge in the right direction! Thanks for any help.
  15. task

    Motion Control

    Finally got it to work after revisiting calculus and trig...glad my intern is a college student with this info still fresh. None of the examples provided with NI-Motion were very helpful except for the "configure buffer" one. Thanks.
  16. task

    Motion Control

    I'm using a PCI-7352 Motion Control board to control my Parker motor (Compax3). I've used this set-up before...two motors, one driving (velocity control) and one absorbing (torque control). My issue right now is the customer's specs state that the velocity has to be a sine wave. I've been trying to modify the "One-Axis Contour Move with Position Monitor.vi" using buffers etc. but it seems the fastest update is only 10ms. I have to run the motor at 2-3 Hz going 180 degrees in both directions (durability testing). I've tried writing my own stuff but with inherent delays the motor does not run smooth. Does anybody out there have experience with using a sine-wave velocity control? Thanks.
×
×