  1. Hi Porter, Thanks for the prompt reply. Yesterday I managed to get it to work to some extent implementing a call to Querry as you described. I think I might also need to modify "MB_ADU_RTU/RX ADU.vi" so that it does not throw an error. At the moment I get 403482 (CRC mismatch). But it could well be that I have missed something in the transaction. More debugging today... Thanks again. EDIT: Nevermind, I was specifying the wrong number of DataBytes. As soon as I set the correct one, the function works as expected.
  2. Hi, first of all, thank you for this great library. I am working with a device that requires extensive use of the encapsulated interface transport (ETI), specifically MEI 13. Your quoted reply seems to indicate that, even thought it is not fully supported, it is possible to use the library to implement ETI. Could you point me in the direction on how to do it? Many thanks, Paolo
×
×