Everything posted by T_Schott
-
QUOTE (marp84 @ May 29 2008, 07:52 AM) you can download an eval from ni.com
-
Report Generation and Executable
T_Schott replied to lraynal's topic in Application Builder, Installers and code distribution
QUOTE (lraynal @ May 27 2008, 09:24 AM) hi is thier a chance that you post the code?? did you use the debug enviroment to debug the exe? -
Is there any way to get file drag events on a File Path control?
T_Schott replied to Jim Kring's topic in User Interface
QUOTE (Jim Kring @ May 21 2008, 03:55 PM) Well, I build my own "file explorer" - using the listbox -timo -
Is there any way to get file drag events on a File Path control?
T_Schott replied to Jim Kring's topic in User Interface
Hi, i use the following events to check the file content: Drag Starting? (alligned to the source) Drag Enter? (alligned to the target) Drop? (alligned to the target) -
like this idea control the data that will be indexed...
-
plotting multiple analog waveform
T_Schott replied to jennifer CLINTT's topic in Application Design & Architecture
hi, search the example for plotting multiple waveforms regards timo another hint: if the settings (e.g. sample rate) of all three channels are equal, you can use one DAQmx read vi to collect the meas. values. physical channels= "Dev1/ai0:2" aquires ai0, ai1 and ai2 for examples use the example finder (daq mx, analoge voltage..) -timo -
Hi, I ve got problems using this tool with LV 8.5. is it my fault?
-
Stop 2 parallels do loops while
T_Schott replied to scls19fr's topic in Application Design & Architecture
change the mechanical action of the button but that s not the best way to handle this problem in my programs i often use one global variable to stop all my running Loops well you can do this with queues oder notifiers - but when you have several loops (>10) you have a lot of wire work you should not use globals for all inter-loop-communications! -
Hi, an easy solution: you can add a global variable an write the value into (you can use a shared variable, too) another solution: using vi server, or reference the vi, get all front panel indicators and select the one you want -timo
-
Hi, in newer DAQmx Versions (since vers. 8 - I think) you can add simulated daq cards to your device manager. perhaps you can do that in labview using the MAX API - but i think that s not what you want to do. you have to check if you can use daqmx with LV 6.1 -timo
-
i found this on the ni ftp: http://ftp.ni.com/outgoing/lv_8_5_1/
-
Hi, what about creating sub vis for each "block diagramm group" making the code more readable -timo
-
HI, here s the hint: VI => Properties => Windows Run Time Position hope this short hint helps timo btw: of course you can do that by propertie nodes
-
QUOTE(orko @ Feb 22 2008, 07:14 PM) the german word for a leaf rake is "laub rechen" and i think a cable rack looks like an upturned leaf rake (ask for a rake at home depot )
-
Hi, in a german it s called "Kabelrechen" => "cable rake" kabelrechen you can buy this from rsonline.de (german shop) http://de.rs-online.com/web/search/searchB...amp;x=0&y=0