Everything posted by jdunham
-
QUOTE (Aristos Queue @ Feb 26 2009, 07:39 PM) It would be cool if the sequence structure could be set to 'auto-shrink' around various VIs or globals to which you just want to add an order dependency (or for whatever reason). Jason
-
QUOTE (benjaminhysell @ Feb 26 2009, 01:55 PM) Thanks! I'm glad it's getting used. QUOTE (benjaminhysell @ Feb 26 2009, 01:55 PM) ... it runs the false conditional disable case runs on the first run through. If I run the unit test again this time the conditional disable will run the true case. It appears that what ever the conditional disable symbol that is set to before I start a run is the one that is actually executed, however if you look at the block diagram this isn't the case. i.e. the conditional disable I want to run is actually 'enabled' yet doesn't run. Well I think that makes sense. These symbols affect how your VI is compiled, but if your VI is part of a running hierarchy, it can't be recompiled. Once your VIs stop, the new symbol is imposed, and then you run again and see the results you expected. Basically you are going to have to impose all of your symbols before any execution of your unit tests, which may require some dynamic VI invocations.
-
QUOTE (crelf @ Feb 26 2009, 11:50 AM) Well I agree with you! :thumbup: My examples were just off the top of my head, since I have (*gasp*) other work to do. The 'overwrite/append' example is straight from the old file I/O VIs and I have to say, the the new version that always overwrites is a big step backward (getting off topic...) I would agree that if an input requires a lot of explanatory labeling, there's probably a bad design somewhere around there. What this thread is really about is that words that add no extra value should not be on your VIs, and I get peeved by style guides that apply those kind of rules like "Always put the default value in parens in the label" or "always make inputs required rather than recommended" or always use "error in/error out" [even when it's totally unnecessary].
-
QUOTE (crelf @ Feb 26 2009, 10:26 AM) Well it's also fine if the default needs clarification or has a special meaning like filter coefficient(0:no filtering) overwrite?(F:Append to file) While I'm on my soapbox, making inputs "required" is a really good thing, and for the most part, required inputs don't need to have their defaults mentioned at all. But that has the same exception, where you may need to clarify a special interpretation of the default value for that data type.
-
QUOTE (PJM_labview @ Feb 26 2009, 09:01 AM) It's not such a big deal on the front panel, but I believe its removal makes the Context Help window (Ctrl-H) look a lot better. I'm fine with default values in parentheses when they are useful, but when they don't add any information, then they shouldn't be there. Maybe the original idea was that first time users might think that wiring anything into that input would signify an error, but it's more likely that "it seemed like a good idea at the time".
-
QUOTE (gleichman @ Feb 25 2009, 01:56 PM) It takes about a minute to go into C:\Program Files\National Instruments\LabVIEW 8.6\vi.lib\errclust.llb and remove the annoying "(no error)" part of the label (don't forget to fix both the classic and the 3D version). That's just about the second thing I do to a fresh copy of LabVIEW after turning off 'Lock Automatic Tool Selection', 'Automatic Wire Routing', and AutoGrow.
-
Property nodes are "upside down" - discuss!
jdunham replied to PA-Paul's topic in LabVIEW Feature Suggestions
QUOTE (gleichman @ Feb 25 2009, 01:56 PM) It takes about a minute to go into C:\Program Files\National Instruments\LabVIEW 8.6\vi.lib\errclust.llb and remove the annoying "(no error)" part of the label (don't forget to fix both the classic and the 3D version). That's just about the second thing I do to a fresh copy of LabVIEW after turning off 'Lock Automatic Tool Selection', 'Automatic Wire Routing', and AutoGrow. -
QUOTE (mesmith @ Feb 23 2009, 11:46 AM) I would agree with this. I think LabVIEW is an awesome system, but it's not that great at creating GUIs. I know that sounds like heresy, but if the LabVIEW-supplied graphs and controls don't do what one needs right out of the box, then it can get difficult in a hurry. For example if you want to add right-click menu items to your graph, or change the plot colors based on the input data values. The OP apparently sounds like he hasn't looked at LV before today, so I don't see the sense in learning LabVIEW just to use its built-in graph when he or she could get very similar results from Measurement Studio using his native programming environment. arif215, what do you want to do that you can't do in Excel, gnuplot or Matlab? If you answer that, we could be more helpful in telling you whether it's worth the trouble to buy and learn LabVIEW?
-
Help with datasocket
jdunham replied to LVBeginner's topic in Remote Control, Monitoring and the Internet
QUOTE (LVBeginner @ Feb 23 2009, 09:03 AM) Well no and yes. XML is just text, so there's nothing to stop you from writing a program in any language and running it on the machine that is receiving the data. However if your using the LabVIEW schema, which was written for NI's convenience more than for yours, then writing that program gets a lot easier if you are using LabVIEW on both ends. -
QUOTE (Ic3Knight @ Feb 23 2009, 01:24 AM) Great. I think your analysis is spot-on. Note that you can use a common subvi in place of semaphores, but they should both be fast
-
The old NI File functions used to append data by default, and now the new ones overwrite by default. NI are you listening? Its sucks! (Sorry to be so grumpy)
-
QUOTE (Ic3Knight @ Feb 22 2009, 03:40 AM) I've never used the simulated device. It's certainly possible that the simulator itself is buggy. If you have a typical NI DAQ card at your disposal, you can set up one of the analog outputs for continuous generation, and then use a pair of wires to bridge that into your analog input, and then you're testing against a real signal. On many of the cards, you can specify that the analog output is stored entirely on the on-board FIFO, and then you will get very precisely timed output no matter what the computer or processor is doing (short of rebooting). Just store one cycle of a sine wave in the analog task and make sure it is small enough to fit into the fifo, and then dig around the DAQmx properties and find where you force it to use the fifo. QUOTE (Ic3Knight @ Feb 22 2009, 03:40 AM) This works to an extent, however in the version I posted, the lower tends to produce a reasonable sinusoid with occasional "glitches", but the top loop produces a sinusoid but with lots of "glitches" which, if observed over a long enough period of time, show that its actually reading back the wrong data: ... The graphs are very interesting, and obviously show that something is wrong. What I can tell you is that I have an application at 1kHz that has been using this technique, with one thread logging to disk for up to a few hours during a run, and another thread doing event-based real-time analysis on the same channel, and it has never shown any kind of data corruption.
-
QUOTE (Ic3Knight @ Feb 21 2009, 08:10 AM) How can you tell there is cross-talk? Your top loop should be producing an essentially random graph. It's just taking the last sample periodically, but with software timing, so there's no strict periodicity to your reading. how could you tell if it's not actually reading the last sample? Without seeing the data, it's hard to know whether it's DAQmx or just your program which produces the aberrant results. The lower loop should be reading continuous data, so if it looks wrong, that's a stronger indicator that you are having problems. It's certainly possible, and maybe even likely, that the property node just affects the task and when you call the DAQmx read VI, it's going to use the effect of the last property node that executed, regardless of which loop that was in. The easiest way to check that is to put the property node and the DAQmx Read VI into a new subvi, and it has to be the same subvi and not reentrant, and then the subvi calls will block each other and you can guarantee that the property node and DAQmx Read are called in the order you are expecting. You could also use a semaphore to do the locking, but a subvi is usually easier. After that, if the output still doesn't look right to you, it's probably not DAQmx's fault. BTW you've made me wonder if the last program I wrote using this kind of trick needs to have some semaphores added!!
-
I still think there should be an option to show the class data rather than the object icon, at the very least on private VIs, and maybe on all VIs which are members of the class. The ability to test VIs by setting the front panel values is so useful in LabVIEW and its so glaringly absent from the LVOOP world.
-
Create control progmmatically to "future proof" program
jdunham replied to dblk22vball's topic in VI Scripting
QUOTE (dblk22vball @ Feb 19 2009, 08:44 AM) If you use an array of clusters, hide the index element (which hardly any non-labview programmer can understand) and show the vertical scrollbar. It's still confusing for people to use the concept of right-clicking on the border of cluster to delete it. If it were me, I would implement a listbox with 1 element selected, and then you could edit the IP address of the selected listbox item in a separate control, and you could have a delete button, and you can show the checkmark symbols to show which ones are enabled. You have to code up all the handling yourself, but it should only take a half day or so. -
QUOTE (Michael Aivaliotis @ Feb 18 2009, 01:41 PM) You da man!
-
I hate to open up yet another discussion of licenses, but can we add the MIT license to the CR submission form. It's pretty similar to BSD from what I read, but I use that license for all my stuff and I'd like to submit a few things under it to the LAVA CR.
-
QUOTE (turbophil @ Feb 18 2009, 10:06 AM) I think you are on the right track; using CD is the way to go. Presumably you know you can have some symbols which are for the whole project, and other symbols that are per-target (it depends where you right-click). You may be able to do what you need by putting the symbol only in the RT target, so that whenever you run on the local machine, it will use a different conditional symbol case. If you need more complex behavior than that, I wrote a VI to change the symbols programmatically, which may help you switch back and forth. I was going to put this in the LAVA code repository, but I can't deal with the bureaucracy today, so here it is, attached (labview 8.6.1). Hopefully later I can submit it the right way.
-
QUOTE (torekp @ Feb 16 2009, 04:48 AM) Well that works, but the error exception part of it should just be a separate VI. I find that I don't want to clear errors in the same place as I want to tell the user about errors. And then the Clear Errors.vi clears all errors which I feel is dangerous because the code will silently suppress any errors, not just the ones you anticipate. It's all fixable with your own code, I just think NI should improve the API so everyone uses the same stuff instead of rolling their own. QUOTE (torekp @ Feb 17 2009, 09:59 AM) OK not ALL file functions, just half. The reading half. Read spreadsheet file, read tdms file, read binary file, etc. (I speak loosely - some of these include the opening of the file, some require a separate opening action, but you get the point.) Well a lot of the new functions already have the functionality you crave (they include the file name in the error message).
-
QUOTE (Ic3Knight @ Feb 16 2009, 02:35 PM) Yes, the cool thing is that your code generally works the same on all DAQ boards, but you can just ask it to do those same things faster if it is an expensive board and/or has a big buffer versus a cheap board that has no buffer at all. QUOTE (Ic3Knight @ Feb 16 2009, 02:35 PM) One more question (sorry!!), if I set up a continuous acquisition task, like the one in the picture I posted last, but never read back any data, will DAQmx throw up an error? Or will it only give the error if I try to read back samples its over-written in the circular buffer? For example, could I set up the continuous task, and then wait an hour (or whatever) and then use the "DAQmx read" property node to get the most recent sample? (I'm not sure why I'd want to do this, but it helps me build a better picture of how it all works!) Yes, absolutely. The circular buffer can acquire just about forever, and it never cares whether you read the data. But as you are finding, if you wait a long time and read with the default read function, you'll get data not found. A corollary to that, never adequately explained by NI, is that just because your read function throws an error, doesn't mean the acquisition is harmed, and you are perfectly free to try a different read from a different position. You could easily have a system which is acquiring very fast, but you are only interested in the data when some other external event happens, like your motion control system gets everything aligned. Then you could record several seconds on either side of the event since your continuous acquisition was buffering the whole time. There is also a 'pretrigger' mode which does pretty much the same thing, but you would have to re-arm the acquisition to do it more than once. Once you have mastery over the buffer you can do anything you want. QUOTE (Ic3Knight @ Feb 16 2009, 02:35 PM) Thanks again for the help! I'm glad I found these forums! Glad to help. I find it frustrating that DAQmx is so powerful, and there are a great many examples, but some of the coolest stuff you can do is entirely missing from any examples.
-
Question about implementing a Delegation Pattern
jdunham replied to Daklu's topic in Object-Oriented Programming
QUOTE (Daklu @ Feb 13 2009, 01:16 PM) I don't believe this is an intractable problem. http://joelonsoftware.com/articles/fog0000000356.html' rel='nofollow' target="_blank">This article from joelonsoftware is somewhat helpful. QUOTE (Daklu) As an aside, I still haven't figured out how to address my problem. I thought about your issue some, but I think there's not enough information for anyone to give you a sensible reply. Not that you didn't give it a good try, but I think if it were easy, you would have solved it on your own, and no one else can know what the really hard parts are. Like when you said "The current architecture is also limited in that multiple connections to a device are not allowed. I could not control the panel via I2C and simultaneously monitor the microwave's serial output at the same time. " It sounds like your architecture is at fault, so then you should fix it, but it's not clear whether you meant that. Is the problem that your class's private data doesn't have the right information, or do you need to add some kind of locking mechanism to your I/O methods? OK, you also wrote "What do I do when two independent Interfaces are competing for the same hardware, such as if the IDIO Device and II2C Device both use the same Aardvark? One could change the hardware settings and put the device in a state the other doesn't expect. I think the solution lay somewhere in the Aardvark Class implementation, but I haven't put my finger on it yet. (Maybe a "Lock Settings" property?)". It seems like you should use a mutex, which in LabVIEW is called a semaphore (near the queue palette, and at some point recently they were rewritten to use LV queues). Maybe you should try to hire a local LabVIEW consultant (obviously you'd need a really good one) just to bounce your ideas off of for a day or so. Sometimes this can be hard to explain to your boss, but it's worth a try. Good luck, Jason -
QUOTE (Ton @ Feb 15 2009, 12:28 PM) Mostly in the system's RAM, or at least that's all you have to worry about. So DAQmx has a private circular buffer system which you don't have to worry much about. Except that the buffer looks linear to you (the offset from the start mark increases infinitely and is a U64 (though you can only access it with an I32 which is just a screw-up on their part--backwards compatibility etc. etc.). But under the hood, it's a circular buffer, so if you try to access data which is too old, you will get error -10846 (which is pretty familiar to people doing a lot of DAQ). Actually that was the NI-DAQ legacy error code and I don't remember whether DAQmx uses different codes. So here's the part you have to care about: The circular buffer size determines how far back into the past you can retrieve data. DAQmx will probably take your sample rate and give you a reasonably-sized buffer (not sure exactly how big, since I haven't mucked with it for a while). If it is not giving you enough, you can ask for more with C:\Program Files\National Instruments\LabVIEW 8.6\vi.lib\DAQmx\configure\buffer.llb\DAQmx Configure Input Buffer.vi I actually thought it was via a DAQmx property node, but either senility is setting in or else they changed DAQmx. Actually I checked again, and inside that VI is simply the property node. The property node is useful because you can change it to read-mode and find out what the current buffer size is.
-
QUOTE (Ic3Knight @ Feb 14 2009, 03:22 AM) No it's just one task, but you need to work with the DAQmx property nodes to control where each thread is reading from. It's more complex than your sample, but nothing crazy hard. Check out this old post about a similar topic.
-
LV 7.1 Convert a Decimal String "1234567899" to an Integer equivalent
jdunham replied to jaehov's topic in LabVIEW General
QUOTE (jaehov @ Feb 14 2009, 11:02 AM) Umm, that number fits fine in an I32. Assuming you are really having a problem, why not use DBLs? Just because it's not limited to integers doesn't mean its a bad choice for them if U32 is too small.