Everything posted by Rolf Kalbermatter
-
Event Structure vs. Variant Queues
Rolf Kalbermatter replied to jfazekas's topic in Application Design & Architecture
QUOTE(PeterB @ Jan 28 2008, 05:43 AM) It means that the event structure might be serving an UI event at the moment the user event arrives and hence not be able to react immediately. A Read Queue waiting for an event to arrive will return instantly or at least as fast as possible, considering the contstraints of available CPU power and load only. Rolf Kalbemratter -
QUOTE(macbeth @ Jan 21 2008, 03:52 PM) Why not show your VIs? Rolf Kalbermatter
-
Constant Wired to Case structure Causes Crash
Rolf Kalbermatter replied to Louis Manfredi's topic in LabVIEW Bugs
QUOTE(crelf @ Jan 17 2008, 08:36 AM) This dialog should only be triggered when upgrading a pre 8.0 VI. So I'm afraid it is probably more a question of a corrupted VI somehow. For some reasons LabVIEW 8.5 does believe it is a pre 8.0 VI and applies that check but then stumbles over something else that is inconsistent in respect to this assumption. A bug? Well strictly speaking the bug happened either when saving that VI in 8.2 or the VI was corrupted somehow in such a way that 8.2 did not have trouble to read it but 8.5 has. It would be of course fine if LabVIEW 8.5 would just inform you of the inconsistency and continue instead of hanging, but there are miriads of things that can be inconsistent and anticipating them all is not very easy and checking them all is even less practical. I do think that technical support would be interested in this VI to be attached to the CAR so that LabVIEW development may look into the kind of corruption and maybe apply an extra check in the VI loader. Rolf Kalbermatter -
Plot legend size changes in built application
Rolf Kalbermatter replied to silmaril's topic in LabVIEW Bugs
QUOTE(silmaril @ Jan 10 2008, 08:26 AM) It may be that you have fiddled with the default fonts in your development environment. Check your LabVIEW ini file for entries like FPFont=, BDFont=, AppFont=, DlgFont= etc. When you change the font settings while you have some control or text setting selected the change applies to that control or text. Without anything selected the change applies globally and will also be written to the INI file if it is not the default setting. An application has its own INI file and by default no Font settings are in there which will cause LabVIEW to use default Font settings. The LabVIEW 8.5 Application Builder does copy some of the INI settings from LabVIEW.ini into an application specific INI File unless you disable that by specifying your own INI file in the build. But I'm not sure if Fonts happen to be among them, as I almost always use customer specific Font settings for Buiild applications. So no, I'm sure it is not a bug, but yes I do think the Font settings and default Font configuration could use some extra explanation somewhere in a prominent spot in the online help. And the Font configuration dialog could be more intuitive. The checkboxes for Panel Default and Daigramm Default are a bit hard to understand in respect to how they influence the INI file and future changes to a VI. Rolf Kalbermatter -
QUOTE(ben5248 @ Jan 24 2008, 07:53 AM) Probably just a change in marketing. Those modules were introduced with cRIO but in the meantime are also usable with the new USBDAQ modules NI sells. So I guess they decided to drop the cRIO in the labeling to not confuse users. Rolf Kalbermatter
-
Communicating with USB DSO without NI-VISA using Driver DLL
Rolf Kalbermatter replied to ashwin's topic in Hardware
QUOTE(ashwin @ Jan 27 2008, 04:56 AM) Forget the queues for a moment. You want to call those DLL functions in a loop or something and test it's return value or it's returned parameter until it gives you the value to tell you it is ready. Then you call the function to retrieve the data or do whatever else you want to do. There is no way to use LabVIEW queues or such directly with the DLL. Once you have the DLL calls working properly you can of course develop a VI library that could give you a queue based interface. But I do not think that would have real advantages over a more direct VI library approach directly. Rolf Kalbermatter -
Event Structure vs. Variant Queues
Rolf Kalbermatter replied to jfazekas's topic in Application Design & Architecture
QUOTE(PeterB @ Jan 27 2008, 06:34 PM) But they execute in a structure that also handles all the normal UI events that WILL switch to the UI thread for sure. And also might contain a timeout case that will also snoop some time for handling. ONe extra point. Queues are very specifically optimized to NOT copy data at all but instead use the reference to the data instead. User events might not be able to use the same optimization in all cases or even at all, especially if you use multiple event structures to receive the same event. Rolf Kalbermatter -
Messaging Using Queues and Notifiers
Rolf Kalbermatter replied to Jim Kring's topic in Application Design & Architecture
QUOTE(ashwin @ Jan 26 2008, 09:32 AM) You can't. For a driver to inform you of something it must implement some kind of event notification. For DLLs there are two possible solutions, they can either allow you to install a callback function that will be called when an event occurres or they can use OS events to inform the caller about such an event. In any case these are things that are not directly translateable into LabVIEW events so you will basically have to write a wrapper DLL that calls your Device DLL with the event notification method that your driver uses and translates it into something more LabVIEW friendly such as a user event or occurrence. C programming knowledge will be required for sure to do that. Rolf Kalbermatter -
.NET Style DataBinding from LV 8.2?
Rolf Kalbermatter replied to Yianni29's topic in Calling External Code
QUOTE(Yen @ Jan 25 2008, 06:52 AM) Yen you are right here, but there needs to be some extra clarification since a LabVIEW refnum is a memory resource too, and I have trouble to believe that .Net will have any influence on the life time of that refnum itself, even if .Net has a very smart Garbage Collector. It may invalidate (but probably won't since the LabVIEW refnum holds a reference to the .Net object) the .Net resource that was referenced by the refnum, (and possibly though not for sure, the Not A Refnum node may be able to detect that too), but it most likely will not dispose of the LabVIEW refnum before the Top Level hierarchy that created it goes idle. So Your concerns are fully valid and Big Hanks claims are likely to be not the full story with using .Net in LabVIEW. Rolf Kalbermatter -
Why aren't you using the VIE LabVIEW HTML Help Generator?
Rolf Kalbermatter replied to crelf's topic in Announcements
QUOTE(Jim Kring @ Jan 7 2008, 08:18 PM) Well that last link talks about IStorage file format. So this would mean it is basically an OLE structured document format just as the older MS Office file formats. The difficulty about this is of course that the OLE structured document format only defines the container structure but not the actual contents in the streams. It's much like XML without any schemata. I'm not sure if chm is OLE structured document format but if it is, I think the description in that document is a bit limited. It may work most of the time but assuming that it will be always like this is going a bit to far. The actual layout concerning the different OLE streams could be changed by adding additional, non-standard streams to the document and suddenly the fixed offsets are not so fixed anymore. Rolf Kalbermatter -
I'm not certified for anything 8-(
Rolf Kalbermatter replied to dgholstein's topic in Database and File IO
QUOTE(mballa @ Jan 22 2008, 10:31 AM) Hi Dan, welcome too. mbella: It's always so amazing what Google can do for you http://performancemicrowave.com/sql_LV.html' target="_blank">SQL LV Rolf Kalbermatter -
Use of TrollTech's Qt in LabVIEW
Rolf Kalbermatter replied to Chris Davis's topic in LabVIEW General
QUOTE(Jim Kring @ Jan 21 2008, 09:10 PM) Not very likely for LabVIEW's UI widgets itself. Porting the existing widget code they build themselves since LabVIEW 2.5 on the various platforms to Trolltech would be a complete horror with many bugs, and functionality they simply can't implement on top of Trolltechs QT. It seems to be related to some of the configuration utilities that got added recently. There is a http://forums.ni.com/ni/board/message?board.id=170&message.id=276416&requireLogin=False' target="_blank">thread on the dark side about it, where someone had troubles with it since his external code (Surround SCM) was using a different version of QT that clashed with the one LabVIEW was using. Apparently the Multi-Variable Editor is the whole story why QT is used and that is in essence a DSC feature only. However as that thread shows the QT libraries are loaded into the LabVIEW process independant if the DSC system is used or not. Why they wouldn't write the Multi-Variable Editor as LabVIEW Vi is a bit beyond me though. LabVIEWs widget tools are quite up to par with QTs. Rolf Kalbermatter -
QUOTE(sara @ Jan 21 2008, 04:43 PM) How about reading the LabVIEW manuals concerning LabVIEw controls, datatypes and especially strings and arrays? Rolf Kalbermatter
-
QUOTE(sara @ Jan 21 2008, 02:51 PM) Well you will have to store it somewhere. A poor mans choice would be a tab separated spreadsheet file to start with. Doing it more complicated would be nice but start out with something that you know you can do. Rolf Kalbermatter
-
Address of an application instance
Rolf Kalbermatter replied to Tomi Maila's topic in Application Design & Architecture
QUOTE(tcplomp @ Jan 16 2008, 01:53 PM) This is no problem for the VI server. It can handle multiple client connections in parallel.There are some application properties (private I think) where you can monitor the connections and I think limit or even drop some of them yourself, but normally it can handle multiple connections. As to the original request, I'm afraid there is no way you can retrieve the remote address and remote port from an existing Application Reference. Injecting a VI into the remote side that you can then execute to retrieve the remote sides local parameters would be the only idea that I have. However I don't think any of the VI server stuff allowing to execute VI code that exists as a memory stream will be accessible remotely because of security concerns. So you would have to get that VI on to that computer in some way that requires physical access to it. Rolf Kalbermatter -
Request Deallocation
Rolf Kalbermatter replied to LAVA 1.0 Content's topic in Application Design & Architecture
QUOTE(tcplomp @ Jan 15 2008, 12:10 AM) That is a very good remark. As it seems to me Mikail has some sort of test application. This is in most cases the ideal application to use dynamic execution of the test steps as in some sort of plugin architecture. Also what I suspect is that he maintains the data in a front panel control/indicator or something through locals. If he would use shift registers, Request Deallocation would not have any influence since the shift register needs to maintain its data between executions. On the other hand shift registers allow programmatic clearing whenever desired. This means that for using shift registers which among other modern constructs like queues is the way to store intermediate data, Request Deallocation is getting rather useless. I feel that Request Deallocation makes no sense in 99.99% of the cases for a properly designed application. Rolf Kalbermatter -
How to set windows date and time properties
Rolf Kalbermatter replied to LAVA 1.0 Content's topic in LabVIEW General
QUOTE(TiT @ Jan 14 2008, 04:18 AM) They do work but they do not return or modify the actual time in DST and non DST format but the current switch over time to start DST and end it. Rolf Kalbermatter -
QUOTE(NateO @ Jan 10 2008, 04:34 PM) While VxWorks is used for the NI-RT targets such as newer Fieldpoint Modules or CRIO controllers I do not think you can just go and install any VxWorks OS and then use that from LabVIEW-RT. The RT OS on those targets definitely has been customized to allow LabVIEW RT to directly work with them. The other option that is more likely to work is the Pharlap OS. NI sells the LabVIEW Real-Time Deployment License for Standard PC's- ETS RTOS which is based on this OS. There you have official support to install a LabVIEW RT supported RTOS on your own computer hardware although there are some specific requirements such as for the network interface. The only other solution I see if you want to use LabVIEW is LabVIEW Embedded. But there you have to customize the environment to interface to the tool chain for your target system, if you dont happen to use a target that is already supported and I'm not aware of an already existing PC104 target. Rolf Kalbermatter
-
Request Deallocation
Rolf Kalbermatter replied to LAVA 1.0 Content's topic in Application Design & Architecture
QUOTE(guruthilak@yahoo.com @ Jan 14 2008, 01:29 AM) You can but it is not a magical wand that makes your programs go faster or work better just like that. In fact it is likely it will make them much much slower. Request Deallocation tells LabVIEW to deallocate all memory that is not currently in use. And that will deallocate memory that a VI that is currently idle may just need 1ms later again to do its work so it has to allocate it again instead of being able to reuse it. Request Deallocation only makes sense when you have a VI that uses lots and lots of memory and only runs once or maybe every two weeks in the lifetime of your application. Doing a Request Deallocation right after executaion of that VI may (or may also not) improve the memory consumption of your application. Otherwise this function causes more trouble than it would solve, which is why it isn't very prominently made available. Rolf Kalbermatter -
SuperPrivateScriptingFeatureVisible for LV 8.2
Rolf Kalbermatter replied to LAVA 1.0 Content's topic in VI Scripting
QUOTE(guruthilak@yahoo.com @ Jan 7 2008, 11:16 PM) The only people really knowing about this are in the LabVIEw development team at NI corporate. And no that license is not for sale! You need to have a very strong case and good connections that anyone at NI will even acknowledge that there is something like such a possibility. I would expect maybe three or so Alliance members worldwide being allowed to use that feature. And no we are not one of them, I use the other methods mentioned elsewhere on this forum for the few times I happen to have time to dig deeper into this. Rolf Kalbermatter -
QUOTE(BrokenArrow @ Jan 7 2008, 07:49 PM) Vi Analyzer is some LabVIEW versions old now and its analysis might have been correct when it was implemented. LabVIEW does make optimization improvements with every new version. That said Build Array is not a complete no-no. Sometimes there is no way around it or it is in a loop that executes only a few times. But it should always be checked and double checked if you do not want an application that gives you way to much coffee time when it is run. Rolf Kalbermatter
-
Pass pointer to array of structs to dll
Rolf Kalbermatter replied to vituning's topic in Calling External Code
QUOTE(vituning @ Jan 4 2008, 11:45 AM) You can't do that in LabVIEW like that. A Byte array (and a string) in LabVIEW is something very different from a C pointer. When you pass such an element to the Call Library Node and configure the parameter as C pointer, LabVIEW will do the translation for you but inside a cluster is something LabVIEW won't do (and in fact can't do without a configuration dialog that would intimidate anyone but the most diehard C freaks). You would need to treat it as an uInt32 and then do the pointer to array data and vice versa in the LabVIEW diagram with the use of more CallLibraryNodes calling into external functions to copy data in and out. As to this function it is not clear if the caller is supposed to allocated the necessary pointers with the required size or if the function will allocate them. In the first case you would need to call even more external functions to be able to do that, in the second case there would need to be a driver provided function to deallocate those pointers again. All in all a real pain and this particular API is very unfriendly to callers in general! It's even hard to call in C and simply a pain in any other environment. Rolf Kalbermatter -
QUOTE(crelf @ Jan 2 2008, 02:35 AM) Very nice Tomi! Congratulations to your insigthful and interesting posts here on LAVA. Looking forward to more of them! Rolf Kalbermatter
-
QUOTE(Kyuubi™ @ Jan 2 2008, 01:46 AM) How about searching through he examples under Help->Find Examples? Gives you a simple example using the Splitter bar! Rolf Kalbermatter
-
QUOTE(aart-jan @ Jan 1 2008, 07:57 PM) If you just want to encode the data after it has been acquired entirely the command line tool approach should work. For longer sound acquisition this may not be desirable and in that case I would simply create an interface to one of the existing open source compression libraries such as Lame, through the Call Library Node. But there is one issue with MP3 that OGG probably wouldn't have, and that is the fact that some companies try to squezze money out of every use of MP3 encoding software. So your application while working technically alright may have legal issues. probably not an issue for a home grown hobby application, but certainly a problem for a professional application. I'm not sure about the "run until completion" true problem though. I haven't seen this yet and I do make use of the system exec regularly. Rolf Kalbermatter