  1. I haven't tested it in anything other than in a development environment, but I believe it will work in RTE as long as the DAQ Assistant VIs are installed. The DAQ Assistant VIs actually call a NI DLL called mxwlvapi.dll, this is what actually does the heavy lifting and I assume this is installed with DAQmx. So theoretically you could create an installer, which has the added installer of DAQmx and this should still work, that is assuming you get the path to the Assistant VIs correctly. I believe there is a registry read that can be performed to help find this. Possibly something like %National Instruments Folder%\MAX\Assistants\DAQ Assistant\common\supportFiles As for how I did it...well, the forums have been discussing very grey topics lately, and one of them is block diagram passwords, and how they have been defeated. So out of my curiosity I started looking into all the VIs that were locked in VI.lib to see if I could find anything useful. I couldn't find much, most of VI.lib that has a password is simply a dll call. AQ has mentioned recently that most of the passworded VIs have been unpassworded to help share with the community and that is apparent here. So I searched my whole National Instruments folder and found these llbs named expressVIsXX.llb with different versions for all versions of LabVIEW. By opening up the daqmxNewItem.vit and daqmxEditItem.vit you can see that it has a control that gets casted to a DAQmxName object, and has code for Channels, Tasks, and Scales. So you can actually use this same code to Create/Edit a Virtual Channel or Task. I'm not sure why this information isn't a knowledge base somewhere other then the fact that NI may choose to change how these VIs work in the future. AQ has mentioned recently the dangers of using code from a password protected block diagram, but I don't believe this falls into that category, because I didn't use any code from a passworded VI, I'm just calling it, and I needed to know the type of input it wanted for a control. Looking at the BD helped me understand what was needed. In any case NI can still choose to change this functionality in the next version of LabVIEW if they choose.
    1 point
  2. I believe if you set a breakpoint in the original, you can cause all the clones to halt at that breakpoint and give you access to them. Kinda annoying but it should work. I too have longed for a clone browser and tried to implement one but failed...
    1 point
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.