All Activity

This stream auto-updates

  1. Today
  2. Feed an array comprised of non trivial equal numbers (e.g. a 1,000 values of 1.2345) to the Std Deviation and Variance.vi of the Mathematics>>Probability & Statistics palette and look at the standard deviation output using a display format such as that shown below: You will be surprised to see that the standard deviation is non zero and within the range of the precision for the type (~1E-15). While this might not be an issue in most use cases, it is still not an potimal result, and suggests that the calculation done in the called DLL is not optimal (it probably uses the standard formula, but because of round-off errors, the outcome is non-zero). I am posting this in the "bug" category, although it is not strictly speaking one, just to warn unsuspecting users (like me), that dealing with floating point numbers comes with its load of gotchas. Here is a snippet to experiment with the phenomenon: Again the display format of the standard deviation indicator needs to be chosen wisely to reveal the round off error.
  3. Hello, I'm trying to run a LabVIEW web service using the HTTPS protocol. I have published my webservice on a windows server. I tested with another machine (client) this webservice and all works correctly. Then I wanted to enable HTTPS on the web service, so I created a self-signed certificate configured with the server's IP address, which I installed on the server and the client machine (my computer). On the client side, I manage to go through the server, but an error message tells me that it can't find the url of my web service method. It's as if my web service didn't exist, but it works if I use HTTP. Below are the images of my web service configuration : I'm also displaying the error I get when I make the request: Thank you in advance for your reply.
  4. Good success with that, but I doubt they have the patience and dedication to build up anything substantial even in terms of numbers of answers to get to some "credit". Let's not talk about the content of it.
  5. Yesterday
  6. I have worked in the past on ADAM5000TCP controllers + modules using this nice toolbox, so it is certainly possible. Unfortunately that was years ago, I don't have access to the hardware anymore and I don't remember details, so I can't be specific. What you describe, though, sounds simply like not querying the right IP, or not having set correctly the netmask on your NIC and in the ADAM (was there an option to do that somewhere? In ADAMview?). Assuming, obviously, that it is not because of a faulty ethernet cable (happens, too). I also think that at some point in the Modbus tester there was a small bug like that if you once had a connection refused (e.g. because of querying a nonexistent register) you had to stop and restart the tester in order to establish the connection again, but my memory is vague on that. Maybe Porter corrected that since then.
  7. Last week
  8. Hello, I'm trying to use LabVIEW with the Modbus Master library to communicate with an Advantech ADAM5000TCP data acquisition device instead of using the original Advantech ADAMVIEW software it was supposed to work with. I'm making this connection with LabVIEW on a different computer than the one that uses the ADAMVIEW software. The ADAM5000TCP is connected to my computer via ethernet. When I try to use the Modbus COMM Tester, I'm unable to Open Port and start the Modbus session, and either get a timeout error or a "Serial port receive buffer overflow"/The network connection was refused by the server." I'm trying to use the TCP communication, am using what I think may be the correct IP address, and the Slave ID is set to 0 to broadcast to all networked devices. With the IP address, I've tried both the ethernet address from my computer, a 169.254..... IP, and the address that is displayed in ADAMVIEW on the old computer, a 192.168.... IP. Do you know what the cause of the issue could be?
  9. What's the purpose of this idiocy? Using AI to create a fake answer to then using it again on it to create a fake thread? I miss the purpose of the spam. To create, on the long term, a fake profile with "credit" as an expert, for social media?
  10. Hello, I am currently working on a project that involves building a 2-way radar system using LabVIEW. For this project, I am using an HC-SR04 ultrasonic sensor for distance measurement and a 5V DC 28BYJ-48 stepper motor for directional scanning. The sensor is connected to my NI USB-6008 digital I/O for data acquisition, while the stepper motor is controlled via an ULN2003 driver module connected to the USB-6008's digital outputs for precise movement control. My goal is to implement a system that can perform left-right and up-down 90-degree scanning, display real-time distance measurements, and visualize the radar scan in a 3D graphic interface using LabVIEW. I am facing challenges with setting up the communication between LabVIEW and the HC-SR04 sensor; ensuring accurate distance measurements, and integrating smooth control of the stepper motor for precise scanning movements within LabVIEW. I have tried configuring LabVIEW for sensor data acquisition and motor control, but I need guidance on best practices ; example code snippets. I am interested in advice on configuring LabVIEW for sensor interfacing, implementing precise motor control, and integrating these components into a coherent 3D visualization. I have checked https://forums.ni.com/t5/Hobbyist-Toolkit/bd-p/react native-linx-toolkit?profile.language=en guide but still need help. Any help would be greatly appreciated. Thank you all for your expertise and support! Best regards,🙂 greatjames
  11. Hello To create a LabVIEW diagram for your 2-way radar system using the NI USB-6008, 28BYJ-48 stepper motor, and HC-SR04 sensor, follow these steps: 1. Set up NI USB-6008 for data acquisition from HC-SR04 using LabVIEW's DAQ Assistant. 2. Control 28BYJ-48 stepper motor via LabVIEW using digital outputs. 3. Integrate HC-SR04 sensor data into LabVIEW for distance measurements. 4. Visualize radar scan in 3D using LabVIEW's graphical capabilities. Hope it helps ! Thank you🙂
  12. Do LLMs edit their posts to appear more human? 🤖
  13. Hi Diac, What in particular do you need help with as you ask about how to implement the whole project! If you have something working with an ESP32 try and mimic the implemention in LabVIEW
  14. Thank for your reply. I have use recetly a Windows tablette and I don't have this problem. I don't kown where is the Windows setting for this paramter
  15. 2-way radar with ultrasonic sensors with left-right and up-down 90 degree opening and 3D graphic display What should I do in labview for this? instead of esp32 I use a NI USB-6008, for the motor a 5V DC 28BYJ-48 stepper motor with reduction + driver and a hc-sro4 for the sensor how to do it? Can someone help me with a labview diagram?
  16. Hi @greatjames don't take this personally but are you are human? I really don't think it is appropriate for an LLM to generate content in response to advice on something as nuanced as a LabVIEW career.
  17. Hello The error you're facing could be due to driver compatibility with LabVIEW 2013, incorrect serial settings, or a USB connection issue. Double-check driver compatibility, ensure correct serial settings (baud rate, parity, etc.), and verify the USB connection. Hope it helps ! 🙂
  18. Hello Many developers in your position consider becoming consultants for more variety and challenge. Networking with other LabVIEW professionals can offer insights into different career paths. Consider your career goals and risk tolerance when deciding whether to stay in-house or transition to consultancy. Both paths have pros and cons related to job security, variety of work, and personal growth opportunities. Thank you
  19. 1. Find the method library file "Management. DLL;" 2. Find the panel directory file "Management. mnu" and change it from read-only to writable; 3. Tools - Advanced - Edit Selection - Visual and Motion - IMAQ Utilities Image Management, Insert - VI, select Management DLL, Select the IMAQ Cast Image method and save the changes. REFERENCE:https://blog.csdn.net/ziseshiya/article/details/139726838?spm=1001.2014.3001.5501
  20. Earlier
  21. I think this is a Windows touch-screen behaviour, due to Windows using press-and-hold to give a right click. Windows waits for the release before sending "mouse down" so it can decide to make it a right click or not. It's annoying but I have not found a way around this.
  22. Hello everyone, I have a button boolean with mecanical action : Switch Untin Released. I used the Event Value Change, when the Boolean is True I move my motor, and when is false I stop my motor. This it's OK when I use the mouse. But when I used my touch screen, I receveid the 2 events when I remove my finger. I add the 2 events Mouse Down and Mouse Up, and exactly the same problem. When I click on my button, the button don't go to the true position. But when I remove my finger, I received the four events : Mouse Down ; Value Change ; Mouse Up ; Value Change. Is someone have an idea why I have this problem?
  23. I will contact both of you to understand your concerns a bit more, since these toolkits (IO-Link for LabVIEW and TestStand) were developed exactly to accommodate the scenarios you describe. I can clarify a couple of things here as well: - Our runtime licenses are always perpetual, never a subscription that could expire. - For development licenses we offer both subscription (to get going for less) and perpetual (if you know you want to use it for a long time). - We do offer discounts on license bundles. So if someone has "hundreds of systems", they could use that option. - The software in question currently has more than 3,000 hours of development time behind it, with ongoing improvements. I assure you, no matter when you begin it will be a long time before you have something that is close to what you could buy today. And at that point you wouldn't consider giving it away for free 🙂. This toolkit parses the entire IODD XML standard, which is huge. It is not quite the same as picking the 2% you need today, and discovering that the next device you want to connect uses a different part of the standard...
  24. ECL Version 4.5.0 was released with CoAP support. Next on the hit-list will be QUIC (when it's supported by OpenSSL properly). I'm also thinking of opening up the Socket VI's as a public API so people can create their own custom protocols.
  25. I am seeing the exact same issue in LabVIEW 2024 (24.1.1f1) 64 bit version. I am trying to build an application that works fine in LabVIEW 2020 but gets this same error 13 with the same description: LabVIEW: (Hex 0xD) Failed to load dynamic library because of missing external symbols or dependencies, or because of an invalid file format. ========================= LabVIEW: (Hex 0xD) Failed to load dynamic library because of missing external symbols or dependencies, or because of an invalid file format. ========================= Shareable board exclusively owned. Method Name: Linker:Write Info To File Was the bug fix applied to the 64 bit version or do I need to wait for another patch?
  26. The Gpower IOLink toolkit looks great but the cost is prohibitive. For $1000 I was inclined to give it a go but I would never saddle up to such a cost on a subscription basis and as you said they are also requiring a annual runtime license. What a disaster that would be for any of my customers when their critical systems stop working on Jan 1st. until they pony up their subscription fees. I think like you I will just dip my toes in the RESTful JSON waters and then see what it will take to generalize it.
  27. We've done a couple one-off IO-Link implementations, but it was by no means an all-encompassing tool that would work with the general standard. We would pay for a development license, but the deployment license costs from the one LV IOLink toolkit vendor were untenable as we have hundreds of systems. We'd be very interested in something like what you described. Please post updates! Is your intention to open source it or to commercialize it?
  28. Now that we are NI/Emerson I would expect to see more connectivity in the automation sector. It seems that IOLink is a dominate communications standard that would be a good candidate for support in LabVIEW. IFM is one company that makes a ton of really cool sensors and networking hubs that are largely IOLink capable. It should be relatively straightforward to develop a restful IOLink interface using GET/POST with JSON formatted commands. I am planning on doing this and was wondering if anyone has gone down this path before. https://www.ifm.com/us/en/shared/technologies/io-link/select-products/product-configuration-pages/dataline-tee-cable-wiring