About This File
This package contains the Plasmionique Modbus Master library for LabVIEW.
		It supports RTU, ASCII and TCP modes with the following function codes:
		0x01 - Read Coils
		0x02 - Read Discrete Inputs
		0x03 - Read Holding Registers
		0x04 - Read Input Registers
		0x05 - Write Single Coil
		0x06 - Write Single Register
		0x07 - Read Exception Status
		0x0F - Write Multiple Coils
		0x10 - Write Multiple Registers
		0x16 - Mask Write Register
		0x17 - Read/Write Multiple Registers
		0x2B/0x0E - Read Device Identification
	
		Other features include:
		- Sharing a COM port across multiple Modbus sessions using VISA locks (10 second timeout).
		- Sharing a Modbus session across multiple communication loops.
		- TCP transaction ID handling to ensure that requests and responses are matched up correctly in case responses are received out of order.
		- Modbus Comm Tester, available through the "Tools->Plasmionique" menu, for testing communication with a slave device without writing any code. 
		- Detailed help document available through the "Help->Plasmionique" menu.
	
Examples are included in "<LabVIEW>\examples\Plasmionique\MB Master\":
Download a copy of the user guide here: MB_Master - User Guide.pdf
Note that Version 1.3.4 of this library has been certified compatible with LabVIEW and has been released on the LabVIEW Tools Network: http://sine.ni.com/nips/cds/view/p/lang/en/nid/214230
The most recent version of this library will always be released on LAVA first before going through NI's certification process.
***This project is now available on GitHub: https://github.com/rfporter/Modbus-Master
What's New in Version V1.3.2 See changelog
Released
Implemented transaction IDs for TCP mode
Added device ID objects to Modbus Comm Tester
Added PDU request and PDU response properties to ADU