  1. Thank you so much, I have question: Or should I copy the source files to the install folder???
  2. You can upload a screenshot in which describe how you can start get the reference to the machine/IP and the executable file. Sure the example will help me more ^_^ Best regards, Thang Nguyen
  3. Thank for super quick reply . So could you please tell me how did you create the reference "Sequence Context in" in the LabVIEW? How to link it to TestStand? I also just posted a question relating to TestStand in this topic: http://lavag.org/topic/11067-teststand-vi-server/ If you have time maybe you want to take a look at this. Best regards, Thang Nguyen
  4. Hi everyone, I am working on a project which require communication between TestStand and multiple LabVIEW executable programs. This project is used for testing the operating of a system which involved different type of controller which is simulated by independent software-in-the-loop or hardware-in-the-loop LabVIEW programs. So far we discussed that the TestStand will be run on a PC which communicated with other PCs which run seperated simulator by ethernet. Each of this simulator are distribution version which is installed as executable on each system, it's not in the developement evironment. I am trying to figure out how to from TestStand I can access and change value of the controls on the GUI of each simulator the set the value as well as read the value as feedback. For this requirement I think about using VI server solution which is get the reference of the controls on the simulator. After doing some experience examples, I found some issues I post here my first question: I tried with some examples in articles on NI web site. This is one example: Controlling Two Executables with the VI Server http://zone.ni.com/devzone/cda/epd/p/id/1366 In the example the Master .vi try to get the reference from the Slave.vi which stored in the same location with the exe file. This is inrealistic with the distribution version where the installation files are not located in the same location with source files. I still cannot find an example which point directly to an executable file, not the vi file and get the reference to the controls on the panel. If you know any information about this, please let me know. Best regards, Thang Nguyen
  5. You should break your topic to more detail. If you want to make a automated vehicle like that then you should ask the question how to drive the motor or what the hardware you should use to build this vehilce. LabVIEW is a programming language which help to communicate with hardware device. You should provide more information other than give a website and ask everyone read it.
  6. Thanks you for your example Crossrulz. I am a LabVIEW developer and a newbie with TestStand, so I would like to ask some question about the way we use the VI in the TestStand. In the first sequences Monitor, the Monitor.vi is called. There is one input which is "Sequence Context in". I cannot find the value for this number and as I understand it's a reference number. I don't know how this value is initialized? In the action "Send TERM Monitor CMD", you call the Monitor Queue.vi to send command to the Monitor.vi. One thing I don't understand is there is no queue reference or name queue is used here. How this queue can link to the queue runs inside the Monitor.vi. Because I only know LabVIEW so I think the way LabVIEW does. Please help me understand this. Thank you, Thang Nguyen
  7. Hi Jdunham, Do you have a link to a NI article how to do this? Best regards, Thang Nguyen
  8. It makes more sense to me when you select this relay module. There is one thing I haven't tell you that I need to measure three tanks like this, so I need 3x3 = 9 channels.
  9. Shaun, Could you tell me how to connect the Sinking Digital module with my controller? I have no idea how to use it in my case without using the relay. I add here my real system diagram. Best regards, Thang Nguyen
  10. I am using NI 9263 Analog Output Module. I found the module you told me, it's NI 9478. It's a $600 one
  11. Hi, I am working on a simulator project. I my project I need to simulate a high level sensor. The controller, I work with, has a 5 VDC output, named A. It connects to 4 parallel 10 K Ohm resisters R1, R2, R3, R4. There are 3 switches connect with R2, R3, R4 and this will be correspondent to low, mid, and high level. Another side of these resisters will be connect to ground. Depending on the switch status, the voltage will be drop at the port A. This is how real system works. I use compactDAQ series C 9172 for my simulator. I tried by using a Analog Output and feeding a voltage output to port A. It doesn't work stable with this solution. I would like to know if there is any hardware which I can change the resister programmatically? I thought about using a digital output to control a relay to open or close switch. That means I have to buy another 16 DO module which will cost $320 more. I would like to know if there is a better solution for this. I would highly appreciate your help. Best regards, Thang Nguyen
  12. Hi, Currently, I can measure the PWM quite good but when the duty cycle is more than 70%, the low pulse time start fluctuate between the low pulse time and high pulse time. This lead to the duty cycle will fluctuate between the right value and 50%. Some one with experience please help me on this. I attach here my test program which has this issue. TestPWM.zip
  13. Hi, The our test engineers can also interact with control based on the coordinator of the controls as Jeff say. But if we move the GUI, everything will be chance, so if I run the test on different day, this will be inconvinient. I finally find this topic at ni after reading about the link given by Dan: Calling LabVIEW VIs from Other Programming Languages http://zone.ni.com/devzone/cda/tut/p/id/5719 Thank you for all your information Best regards, Thang Nguyen
  14. Hi, I would like to know if there is any way to access the controls on the GUI of application made by LabVIEW from other programming languages? I am working on building the applications for my company. Now other engineers from testing department asked me if there is anyway they can do some scripting which can access to the control on my applications. They use Quick Test Pro or some test tool like that. Usually this will be done with applications written by other programming languages or using TestStand. But our company doesn't have TestStand. So if you have any experience about this case, please give me some recommendation. I appreciate your time for reading and answering my question. Best regards, Thang Nguyen
  15. I think you are right. Sometime the problem is not too complicated as we thought LOL. If there are something new, I will let you guys know. Thank a bunch.
  16. Hi, Currently, I am having the same problem with 2 parallel loops. One loop I got data from CAN and put data into the queue. The second loop will process data from the queue. One weird thing is if I put the breakpoint in the second loop, it runs. If I don't use the breakpoint, I will not run. Could you tell me what should I do? Thang Nguyen
  17. QUOTE (Mark Yedinak @ Apr 1 2009, 04:17 PM) Thank Mark, I change to use share variable already. This is more efficient in my case.
  18. Hi, I am trying to make the TCP work follow the Simple Data Server and Simple Data Clien in the NI Example. I am not sure but the communication is not correct rignt. I attach the screenshot here. The client receive is inside a time loop at dt=100ms. The Server send is inside a loop at dt = 100ms.
  19. Hi, I need a solution to communicate between 2 lapview programs which need to provide a stable and robust connection status because the time is cirticle in my project. These two programs send and receive command and data to each other. I already tried with TCP/IP VIs but it didn't work well. The reason maybe be the result of currently one of my program using the TPC/IP to communicate with a CAN device though a TCP/IP virtual server. And this communication is interfered so either I lost signal on the CAN or my TCP listener got timeout. I wonder should I use datasocket in this case or not? In this case I have questions: 1. Cause two program are write and read, so should I make them both publisher and receiver? Can I do that? 2. To send out multiple variable should I use different URL for different variable? 3. In this presentation example: http://zone.ni.com/devzone/cda/tut/p/id/5168 They just use directly the DS Read and Write with the URL while in the example of LabVIEW DS Writer and Reader, they use the Launch DS server if local URL. Should I use this VI? And in case I need to read or write multiple variables, should I use each of this VI for each variable? Thank you for your time. Best regards, Thang Nguyen
  20. Hi, I would like to know if there is anyway to create and pass the reference of an object programmatically? I will tell a little bit about my current project. There is a main VI which is the main window control of the system. I have many different classes in the project but for this example I will talk about two main class which is the map and the vehicle. When the program is initialized the vehicle object is created first and the reference of this object is passed as an initialize data for the map object. The pass by reference is implemented based on the method introduced by Jim Kring. The process of the map object will read the property position of the vehicle to plot it on the map display. Now I have to develope my project to another level which is plot multiple vehicles on the map. These vehicle is generated programmatically. As I said, my map object has only reference of the initializing vehicle. I don't know how can I pass the reference of a new generated object to the object I had already created. I highly appreciate your time for reading and answering my question. Best regards, Thang Nguyen
  21. QUOTE (Mark Yedinak @ Mar 5 2009, 09:29 AM) I am talking about during the software running. If the enum stay seperately I think I can handle it, but it's stay in a cluster and reference from subVIs.
  22. Hi, I would like to know is there anyway to replace an enum or it's content in a cluster programmatically. This cluster is used as a control on Front Panel as well as updated value by subVI though reference. I found a topic talking about replacing the content though the reference directly to the file of the control .ctl. I just wonder if it works in my case or not. Best regards, Thang Nguyen
  23. Hi, I would like to replace an enum control in a cluster programmatically. This cluster is on the GUI and is also controlled though reference. I would like to know if I can do that by this solution? What I worry about is the ref is pass to sub VI. When I modify anything in the cluster, the reference contant also change and need to be replaced. I still not try this but is this true I can change the control at the path and it will update immediately in the program? How it happen with excutable and install version? Thang Nguyen
  24. QUOTE (gleichman @ Mar 4 2009, 03:22 PM) Thank for your information.
  25. Hi, After having CLD and working for a time, I am thinking about going to next level with CLA. Cause this is kind of essay test so I know that my working experience is not enough. I would like to know which material I should read or is there any good resource I should reference to? Best regards, Thang Nguyen
×
×