Jump to content

Mads

Members
  • Posts

    446
  • Joined

  • Last visited

  • Days Won

    28

Everything posted by Mads

  1. There is no change when it comes to Real-Time support now with 5.0.4 right? Still need to stick to 4.2 to use it on RIO-targets?
  2. I agree, with the former๐Ÿ˜‰ It is time to pause the planning to redecorate the kitchen when there is a fire in the living room (no matter how fire retardent the new paint is going to be).
  3. Here is one quick draft of a VI for 2D searches. You might also save it as a VIM to use it on other types of 2D arrays... Search 2D Array.vi
  4. One important thing to note is that if the application was built with the "Pass all command line arguments to application" key checked the OS Open Document event is never triggered ๐Ÿ™ (come to think of it this might be why it has not worked as expected in the past ๐Ÿค”). This might be a show stopper in cases where you *sometimes* want to be able to launch the app with additional/other arguments, e.g. to trigger some special behaviour. We do that to allow system administrators to disable some features in the application depending on the user's access, or point the application to an alternative configuration e.g..
  5. Yes, it does work ๐Ÿ™Œ When that tip first got out way back it did not seem to do the job properly, but it does now, in LabVIEW 2022 at least. I could not get the filter-version of the event to give me anything for some reason, but the regular does and it picks up opening multiple files together. (Looking at the issue again earlier I noticed VIPM e.g. still uses the helper app (VIPM File Handler.exe), but perhaps that is just a legacy / if it ain't broke, don't fix it thing. This is "supersecretstuff" too though, so trusting that it will continue to work is another issue.)
  6. Command line arguments is fine for the initial launch, but the helper app is used to also pick up double-clicks on associated files when the applictaion is already running.
  7. Oh, I knew. I just like to poke dormant threads (keeps the context instead of duplicating it into a new one) until their issue is resolved. Only then can they die, and live on forever in the cloud๐Ÿ˜‰
  8. The "LVShellOpen"-helper executable seems to be the de-facto solution for this, but it seems everyone builds their own. Or has someone made a template for this and published it? Seems like a good candiate for a VIPM-package ๐Ÿ™‚ (The downside might be that NI then never bothers making a more integrated solution, but then a again such basic features has not been on the roadmap for a very long time๐Ÿคฆโ€โ™‚๏ธ...)
  9. Did you figure out this crash @smarlow?
  10. Here is a good thread that covers various related scenarios: https://forums.ni.com/t5/LabVIEW/why-open-new-clone/td-p/2976973 Regarding the queue; if it is not in use anywhere (regular dequeue e.g.) so that the close can be detected there? If it is polled in the timeout you probably do not need to run that timeout every 10ms as that will put a high load on the CPU. For users to perceive things as "real-time"/instant anything below 300 ms or so will do. You can also wire the error wire directly to the stop terminal unless you have other cases there that generate a boolean, then using the status alone is more practical..
  11. Not having looked at the details of the code you have, here is a quick general comment: If the dynamically called error monitor needs to close if the main VI closes I would not code that by having it monitor the boolean of the main (reading values using property nodes is not optimal in any case, globally or locally), but rather destroy the queue in main when it closes and then have the dynamic VI react to the queue erroring out, or use a dedicated user event, notifier or channel wire to message this (bidirectionally if needed). (There are countless ways to do this, all with their pros and cons. A named "System" notifier e.g. that is used for any part of the application that needs to know when to gracefully shut down, reload setting etc. is *one* simple solution that allows anyone to monitor it without polling or having anything pre-wired (just mentioning one such solution here is opening up for a bunch of protests from people preferring other methods due to cons with this particular method, but anyway...))
  12. Any code can contain errors. If you script the code you are just adding another layer where you can have errors (the script itself, in addition to the code it generates). When the script has created the code you still have to test the generated code to see if it works correctly. If you write it manually and test it (easier than testing scripts as you can test its intermediate steps directly as you progress) you can use that code for all ports, not just for one. Having to repeatedly create complex but similar code from scratch could justify doing it with scripting to reduce the risk of human errors, but here you can still handle it by having the code cover all scenarios and/or with code reuse . And much of the code has been written and tested for you already (examples) so all you need to do is add whatever extra functionality you need and test those changes. Have you tried solving this the easy way by relying on the RT OS and VISA support already, but observed that it does not meet the your reliability requirements? Or have you just assumed that it will not and are optimizing it prematurely, making the path to a working solution unnecessarily hard and complex?
  13. Yes, I never said they did, but I did wonder why you need to script their creation.
  14. The top one, the SAC, will run even if the root loop is busy, AND allows you to set the inputs. This function was not available in LabVIEW until version 2011 or so. It is especially useful if you need your application to spawn VI clones to handle various events (TCP session handlers for example) regardless of what the user is doing in the GUI... The two bottom ones will be blocked if the root loop is busy, e.g. if the user happens to be viewing the time picker of a time control it will halt until the user closes the time picker. Before the SAC was introduced in LabVIEW you had to use the run method (bottom one) if you wanted to avoid having to wait for the dynamically launched VI to complete (it has the Wait until done input). The Call by reference node on the other hand had the advantage over the run method of offering control inputs to the call whereas the run method would require you to use set control invoke nodes for that. Here is a long thread about the root loop issue from before the SAC was introduced: https://forums.ni.com/t5/LabVIEW-Idea-Exchange/Calendar-control-that-does-not-block-the-GUI/idi-p/1417794?search-action-id=359039184054&search-result-uid=1417794
  15. And to do that you can use the examples you find if you search for 987 in LabVIEW examples. But you are for some reason also trying to script the creation of such code, is that an additional requirement or could you just edit the examples and compile it into your bitfile?
  16. The 987x modules *can* be accessed just like any other in-built serial port (using the VISA serial functions) as long as you have installed the 987x support package on the cRIO (option that should be available in the list when you choose to install the system image etc on it). No need to even think about their connection to the FPGA then. Now, before that support package was available you did need to add FPGA code, but even then that code is available as an example so you do not need to figure much out anymore...We used the FPGA-method 15 years back or so, now we just install the support package and use it with VISA.
  17. We do not have anything identical, but I do relate. The rate of critical bugs on cRIO seem to have risen. We currently have cRIO-9030 and 9041 devices that run fine for anything from 1 day to 3 weeks and then kills an application that we had no issues with prior to moving from 2018 to 2020. No worrying memory-, CPU- or disk usage up front - and nothing in the error logs. Tedious troubleshooting. There was a recall of some 9030s not so long ago too due to faulty components. On some there are even issues with the BIOS (>50% CPU usage when idle anyone...?). The known issues lists contain quite a few serious bugs too. Simplifying the RT application until the issue goes away is a tredious enough strategy. Add all the recent BIOS, OS, LabVIEW and driver issues and you are in a world of fun... Here is a similar scenario from 6 years ago:
  18. Ah. Linux RT support is the big thing for us . We used ot have some VxWorks targets, but those are obsolete now. I'll revert back to 4.2b.
  19. The RT Image folder does not seem to be updated with the newly released version 5 of OpenG Zip...How is the process to install it on Linux RT targets now? I looked for an .so file for 5.0 or an option to install it in NI Max, but have not found it yet?
  20. So you do have modbus communication, but the problem is that you *sometime* get a timeout? You are able to read/write data from the device, it just is not stable? If so the serial port seems to be working and all you probably need is to tune the timeout parameter or troubleshoot the device that replies slowly or not at all on some polls...What are the timeout parameters in this driver and their values? I would connect a simulator instead to the port (ModSlave32 e.g. if the device is a slave,or ModScan 32 if it acts as a master...You can also run a trial of our Modbus Master that can be downloaded here: https://www.clampon.com/products/software/modbus-test-master/) that will let you view/ debug the communication (how often does it poll, do the poll commands look OK (can be verified in online verification tools e.g.) and does it timeout even if the simulator sent out a reply etc...). Using a simulator tool to verify that the connected device replies as it should if connected to that is also a good thing to do. (If that is not what you meant I would test this without involving Modbus or anything first. You can use a terminal program on the PC you connect to the serial port. We have one written in LabVIEW that simple to use, it can be downloaded here: https://software.clampon.com/ClampOn_Serial_Tool_CurrentVersion.zip On the sbRIO you can run one of the serial IO examples that just initializes the port, writes something and reads...then check with the terminal program if you get what you wrote and read whatever you send from the terminal program. Once you have basic serial comms workingyou can go back to the modbus driver and see if that has any issues when the basic functionality is OK. If it does you take it from there..) I've never had a need for NI Serial on any of our cRIOs or sbRIOs, only VISA and as you say the support for 9870/71 add-on...Perhaps they just list that driver as needed to cover the case where it is actually used with equipment that requires it? You could try to download the NI Serial driver separately, but normally NI Package Manager should present it as a possible option during software installation from NI Max, especially if you are using a system image.
  21. NI Serial is not required for the use of serial ports built-into the sbRIO-9627, only VISA. So that is not the problem. I would try to simplify this down to a simple VI that initializes the port and tries to read or write to the port. Check if the initialization returns any errors and whether you get any data in or out of it (connect a PC with an RS485 uinetrface to the RS485 port and see). Note that if you are using 2-wire RS485 you will need to set the port in 2-wire mode for it to work... (I would also stick to the 2020 RT RIO-install instead of the 2021 system image, but that's an unrelated story... )
  22. No they did not have one (too busy with Emerson this time around perhaps), but they have opened one *now* to get feedback: https://forums.ni.com/t5/LabVIEW-Public-Beta-Program-in/bd-p/labview-2024-beta
  23. Ran into another 2023Q3 issue with Matrix functions as well when buidling another application in the same project, the solution to that has been discussed here already though: https://forums.ni.com/t5/LabVIEW/Impossible-to-build-a-working-EXE-in-2023-Q3-if-matrix-functions/td-p/4327930 I'll test today if any of these issues have been addressed in 2024 Q1...(not discussed in any of the release documents so far as I can see).
  24. Now that 2024 Q1 is released maybe we can just skip to that ๐Ÿ˜ฎ It will be interesting to see if the issues highlighted in this thread has been resolved(?).
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.