Jump to content

Search the Community

Showing results for tags 'labview'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Software & Hardware Discussions
    • LabVIEW Community Edition
    • LabVIEW General
    • LabVIEW (By Category)
    • Hardware
  • Resources
    • LabVIEW Getting Started
    • GCentral
    • Code Repository (Certified)
    • LAVA Code on LabVIEW Tools Network
    • Code In-Development
    • OpenG
  • Community
    • LAVA Lounge
    • LabVIEW Feedback for NI
    • LabVIEW Ecosystem
  • LAVA Site Related
    • Site Feedback & Support
    • Wiki Help

Categories

  • *Uncertified*
  • LabVIEW Tools Network Certified
  • LabVIEW API
    • VI Scripting
    • JKI Right-Click Framework Plugins
    • Quick Drop Plugins
    • XNodes
  • General
  • User Interface
    • X-Controls
  • LabVIEW IDE
    • Custom Probes
  • LabVIEW OOP
  • Database & File IO
  • Machine Vision & Imaging
  • Remote Control, Monitoring and the Internet
  • Hardware

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Personal Website


Company Website


Twitter Name


LinkedIn Profile


Facebook Page


Location


Interests

  1. Hi! I am looking for a Senior Software Developer to work on our LabVIEW based sensors and applications. I am also looking for Senior Software Developer(s) available for contracts (somewhat local to London) . Please note that this is about product development in LabVIEW (as opposed to test development). More info here: https://silixa.com/about-us/careers/
  2. At JKI, we have found that a professional user interface design can make a huge difference for LabVIEW applications. That’s why we’re very proud to announce we have just released the JKI Flat UI Controls for LabVIEW, a beautiful, professionally-designed set of LabVIEW controls that we use on some of our own projects at JKI! We hope that by sharing these with the community, we can help make it easy for just about anyone to build their own beautiful and intuitive user interfaces in LabVIEW. Learn More & Download
  3. Hello, everyone. Recently I came across one issue, that I solved within a couple of minutes in Simulink, but cannot crack for a couple of days in LabVIEW. It is a Rising integrator (model and plots from Simulink attached). Mod is the modulus function (i.e. remainder), the integrator reset is triggered by the external “Trigger” signal at 1 sec. After that, as you see the integrator generates a ramp signal. I was trying to represent the same behavior in FPGA LabVIEW in order to use it further on my cRIO. I’ve seen on the forum, that one of the most feasible solutions for the Quotient & Remainder function (i.e., Modulus in Simulink) is the use of a while loop system with subtraction. But the behavior of the system is different since it generates a ramp signal after the reset is on, but it has a negative slope and saturates at -37k. Just to check in general how the approach works in LabVIEW, I’ve designed the second model with a Quotient & Remainder block (I know that for FPGA it is not the best option, plus I could not figure but how to use it with FXP values). But this model generates the output with a value of 5. Which is even more questionable. In this case, could you please advise what I am doing wrong with the FPGA code for the block? Since FPGA is the main reason, why I am looking for any options but not to use the Quotient & Remainder block. Thank you in advance. P.S. The models are designed in LabVIEW 2014 SP1. Integrator_SGL.vi Integrator_while_loop.vi
  4. Hi all, We're excited to announce the public release of TVI – our industry-proven test management framework for LabVIEW: http://tvi.co TVI is a flexible and easy to use test sequencer and reports generator for LabVIEW based functional testers. Key features: Simple and easy to use user interface Very short learning curve Creating test sequences in few clicks Viewing results in real time Exporting of data in various formats (CSV, PDF, HTML) Seamless integration with LabVIEW enables to write/edit tests directly from TVI (developer mode) Editing sequences and test parameters on the assembly line stations (runner mode, no need for LabVIEW) (TVI does not require TestStand to run) See it in action here: https://youtu.be/7Job4qMc66w We’d love to get any feedback! Thanks, Avital
  5. LabVIEW Software Developer SIGMADESIGN is a fun, fast-paced engineering consulting company currently experiencing explosive growth. We are looking for a LabVIEW Software Developer. Curiosity, competency and confidence are a must. We offer competitive compensation (DOE), Medical, Dental, and Short Term Disability insurance, a retirement plan, and profit sharing. We also offer Voluntary Benefits: Vision, Long Term Disability, and Term Life insurance. Primary Function: Definition and programming of LabVIEW based software. Duties include: designing, developing, installation, and debug of custom LabVIEW based applications for a variety of monitoring, measurement, and control systems. Systems will incorporate a variety of technologies (DAQ, machine vision, motion, FPGA & real-time control, etc.) with application across a broad range of industries. Essential Job Functions - Responsibilities: · Develop and maintain LabVIEW applications for control and data acquisition across a wide range of test and measurement systems. · Interpret and understand control specification documents, P&ID drawings, wiring diagrams, and schematics. · Utilize National Instruments data acquisition hardware, off-the-shelf test equipment, and custom developed hardware. · Troubleshoot software and electrical control issues and define and/or implement solutions. · Support, improve and modify existing LabVIEW applications as necessary. · Create and maintain documentation, version control history, and bug tracking for LabVIEW applications in coordination with engineering and technician teams. Required Education, Skills, and Experience: (Knowledge, skills, & abilities) · CLD (Certified LabVIEW Developer) certification or above is required. · 5+ years LabVIEW application development experience with demonstrated proficiency. · Experience with NI DAQmx, NI VISA drivers, and supported protocols (GPIB, RS232/RS485, TCP/IP). · Experience with at least one version control system and an issue tracking system. · Attention to detail in design, programming, debug, and documentation work. · Ability to organize and prioritize numerous tasks and complete them under time constraints. · Ability to plan work and accomplish objectives with minimum of direction. · Strong written and verbal English language communication skills. Additional Desirable Skills, Education, and Experience: · CLA (Certified LabVIEW Architect) certification highly desirable. · Bachelor’s degree in Engineering or a related field highly desirable. · LabVIEW Real-time and FPGA Programming experience. · LabVIEW Object-Oriented Programming experience. · Experience with developing Motion and Vision applications. · Experience with CAN and Modbus network protocols. · Familiar with basic relational database concepts. · Linux OS administration and shell scripting experience. · Experience with Matlab and Simulink. · Additional software skills (C/C++, PHP, Python, etc.). · LabVIEW for calling external code (dll, COM objects, ActiveX, .NET, etc.) · Translation of source code from various languages (VB, C, C++, C#, Python) into LabVIEW code. · Calling VIs dynamically. · Experience with LabVIEW version 2012 or newer. · Pass a post-offer background check verification. · Complete Pre-Employment Assessment required: Begin Assessment In addition to submitting your application, please complete the Pre-Employment Assessment to be considered for this position. Work Environment: Standard office environment with normal amounts of office related conditions. Occasionally may be required to work in environmental conditions that emulate typical user environments in order to facilitate design testing and validation. Sigma Design - Corporate Fact Sheet.pdf
  6. Hi, Zernike polynomials are extensively used in Vision science, adaptive optics and optical metrology to represent different type of wavefront aberrations. I am currently working on a labVIEw project that require the Zernike surface fitting to the experimental data. I can write the code myself but it will take little longer. want to know if anyone in this group has used the Zernike polynomials and willing to share the LV code? plz feel free to respond. Cheer Jimm
  7. Hello, I am trying to use classical touchscreen moves on my LabVIEW application. The problem is I really don't know how read the information coming from Windows indicating the type of move (zoom rotate, span,...)! I tried to use the Windows message queue library (using user32.dll) with the message WM_TOUCH and WM_GESTURE but nothing works. I don't know if it's compatible... Does anyone tried to do this? Thanks for your help!
  8. Hello to all. First of all thanks a lot for reading this post. I have a while with event structure. The event structure has the next two events: · Timeout: each 25ms, this timeout reads variables from PLC. · Button event: When user press this button, a dialog box appears to ask "yes or no" to user. Well, here maybe there is a problem because if usser takes more than 25ms to enter an input in dialog box then timeout does not run in that iteration and It is critical for me. Is there any way to do that program runs and it does not stop until usser put an input in dialog box? Or the best way is to do another event structure in another while with button event? Thanks a lot.
  9. Hello to all. I have an image and a ROI. I would like to get the minimun distance between the first edge and the last edge in horizontal position. See image attached. If every edges found are in color yellow I would like to get the distance between edges in red (minimun distance from last edge to last edge in horizontal direction. I have tried to use "IMAQ Clamp Horizontal Min VI" but this VI does't the option "from first to last edge" and the only way to get what I want is to play with contrast but it is not work for some of my images. So is there any way to get what I want? Here is the image. From fist edge to last edge I mean from left to righ, the first edge found and last edge found. Thanks a lot.
  10. Hello to all. I have an application wich use; imaqdx (displays...), sliders, many controls and many indicators, and everything in a tab control of 3 pages and 2 subVI. I am trying to use "write and read panel to/from ini . vi". The first thing that my program does is to read panel from ini. Here there is the first problem because it gives the next error: "Error 91 "The data type of the variant is not compatible with the data type wired to the type input. Set control value" Here is my piece of code in image attached (boolean input in open.vi is True). I notticed that it gives me an error if the .ini file does not exist (but it should work even .ini file does not exist). Well, my next step was to create a .ini file before to use "read panel from INI.vi". So I use "write panel from INI.vi" and it works fine. It does not give me any error. and the ini file is the next: [medir.vi] Boca = "0,000000" Camara 1 Configuracion = "\00\00\00\1Dremote image 0000000013F9C704\00\00\00\0Anivissvc.*\00\00\00\13LV_ImageDTClassInfo\00\00\00\01\00\13)É\00\00\10\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\10\00¬\00\00\00\00\00\00\00\1D)\13\00\00\00\00\00\00\00\00\00<\04\00\00\00\00\00\00<\04\00\00\00\00\00\00\03\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00€\04\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00DÊù\13\00\00\00\00LÌj\0F<\1E\00\00ø\08\00\00\00\00\00\00\00\00\00\00\01\00\00\00\01\00\00\00\00\00\00\00\1D\00\00\00\00)\13\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00remote image 0000000013F9C704\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\0ÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿúïêôÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿËž“Š„€z€}{zzwx|{wwxswyvttquvrtqpprqsrpvppsquqqusputquxusswwssttvwtwt}yqvuxuzvvuwtwvvtvrwrqpupgc\\XYZX\\XW[[UVVWUXTRTRURUQQSPNQNNOKKLKLJLJFEDEEBBC?B??=:>@CDHGHHIJGJEGDFEHJGFDBADDCCEDBCFILS^ao€–³Òñÿÿÿÿÿÿÿÿÿÿÿÿ\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00ÿÿÿÿÿÿÿÿÿÿÿÿÿÿìÛËÚ̾¶³³³¼³Àìÿãϸ¬ª£¤œ‘‘‹Ž‰Œ‡…€†~z~}x{||}z~xx}}v{syx{vwwwzyywxxxxwwuruwzyvwszvzt{z{yv{wy|{vyw{zzwy~y}xzz}y{|€†€‚€€‚ƒƒ†}‡ƒ…‡‡†‹ŠŒŒŽ‹‹•š’–”›žœ› ¡¢©©©±²µ¶º½ËÒåÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿýëä÷ÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿ Ž‹…†|ƒ}~xv~z{zu{wvvvuutvssqssusotqrwruxtrpqrrotusrvuwywrsuusyxvywxtvsvwuuwvwywquvvuvswtvqpplge^\\VYWYXWYXSWVUZUVQSUTSRTTUNONMKMMKKMJLLLJGEDC@CA?@@@??=CBDGGJLJIJGGIGHEFGFHHCBCBADCAADDIOWZiq„œ·Ôïÿÿÿÿÿÿÿÿÿÿÿÿ\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00ÿÿÿÿÿÿÿÿÿÿÿÿÿÿåÙ×âɺµ®¶¶³·ÍýÿßDz¨¤¢¥š–“‰ˆ‰…‚‚‚~~z}x}}~xxxwyy}xwzwzvywuvxyuxtvyxvvwtyqvpzv|zvzzy{xzzzxx{yxyzyzxw}{y~{}|~€{{|‚‚„ƒ‚…‡€{‚‚„‚‡Š‰‡‰Š‹ŠŒ‰ŒŽ‘Ž’••’“š™žš™›Ÿ¡§ž£ªª®²´»½ÂÉÚïÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿøàéÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿô»žŒˆƒ€~}~}||w{yzxuwwuxvrtvtvtrqpuotqppttvtxsstqqtrtpswtwwvsusuvwxxxxvxuxxvvtx{ux{uuvttxtsssspoja\\Z\\YYZXWYWSSWXWWUSRPTUQSRNQPQNOLNLLKJJIHFFHECA?A?><@?=?ADHFELIHHJIIGEHFGJJDEFBCBECEACDGJPX_fs‡¢»Úóÿÿÿÿÿÿÿÿÿÿÿÿ\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00\00ÿÿÿÿÿÿÿÿÿÿÿÿÿÿé×Ýã¾·®´´Âº»Ò Camara 2 = "0,000000" led_boca = "FALSE" Buena_boca = "0,000000" mala_boca = "0,000000" Espiga = "0,000000" led_espiga = "FALSE" buena_espiga = "0,000000" Bulbo = "0,000000" led_bulbo = "FALSE" buena_bulbo = "0,000000" Cuello = "0,000000" led_cuello = "FALSE" buena_cuello = "0,000000" mala_cuello = "0,000000" Cuerpo = "0,000000" led_cuerpo = "FALSE" buena_cuerpo = "0,000000" mala_cuerpo = "0,000000" Excentricidad = "0,000000" Buenas = "0,000000" Malas = "0,000000" led_excen = "FALSE" EXCENT = "0,000000" Camara 2 Configuracion = "\00\00\00\15Threshold Destination\00\00\00\0Anivissvc.*\00\00\00\13LV_ImageDTClassInfo\00\00\00\01\00\00\00Á\00\00\10\0000\00\00\03\00\00\00\00\00\00\00\\00\00\00\00\00\00\00Threshold Destination" Excentricidad.<size(s)> = "6" Excentricidad 0. = "<size(s)=0> " Excentricidad 1. = "<size(s)=0> " Excentricidad 2. = "<size(s)=30> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" Excentricidad 3. = "<size(s)=30> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" Excentricidad 4. = "<size(s)=30> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" Excentricidad 5. = "<size(s)=30> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" Nivel de luminosidad = "157,666672" led_luminosidad = "TRUE" Distancia promedio = "46,131313" Bordes encontrados = "33" Camara2_grafica = "0,000000" Dist_Cuerpo_Cnfig = "0,000000" Dist_Boca_Cnfig = "0,000000" Dist_Espiga_Cnfig = "0,000000" Dist_Bulbo_Cnfig = "0,000000" Largo total = "0,000000" led_largoTotal = "FALSE" cuello_config_cluster.Left = "0" cuello_config_cluster.Top = "0" cuello_config_cluster.Right = "0" cuello_config_cluster.Bottom = "0" cuello_config_cluster.Rotation = "0,000000" top_cuello_prod = "0" botton_cuello_prod = "0" PLC_Valor_Cuello = "0" ampolla_ok_prod = "FALSE" num_disparo_cam1 = "0,000000" PLC_Valor_Espiga = "0" PLC_Valor_Cam2 = "0" lim_min_ambar_boca = "0,000000" lim_max_ambar_boca = "0,000000" Largo Total.<size(s)> = "1" Largo Total 0. = "<size(s)=0> " Tab Control = "Camara 2" Cluster.Numeric = "0,000000" Cluster.Numeric 2 = "0,000000" Cluster.Numeric 3 = "0,000000" Cluster.Numeric 4 = "0,000000" Cluster.Numeric 5 = "0,000000" I resume "camara 1 configuration" because the rare symbols are about x10 more. Well, next step is to read this .ini file and now it does not give me any error but it stacks in "read panel from ini.vi" (maybe it takes about minutes for reading .ini). How can I do to write and read panel to/from ini well? It is very important for my application. Maybe there is another library that I can use? Thanks a lot!
  11. Hello to all. I think this is an interesting topic and it isn't easy to find out on the internet. I would like to know (more or less) what is the price that a company pay to another for an applications developed in labview. I am new in that and I have to develop a product and I don't know which price I should ask for. Apart of hours worked, gas etc etc I would like to know the market price more or less of these applications. My application I have to develop is an artificial vision application which will use "Vision Adquisition Software" and "Module Vision Toolkit". I am asking for (more or lees) about the market price of the software (not the hardware). Thanks a lot.
  12. https://m.youtube.com/watch?v=v6X4QkYQTZU&feature=youtu.be
  13. Hello to all. First I explain my environment and then I will ask the question. PC 1 (development PC): intel i5, windows10 64bits, 8GB Ram, Labview 2015 SP1 (32 bits), Vision Adquisition Software 2015, Module Vision 2015, DSC 2015, ni OPC Server. PC 2 (deployment PC) : intel celeron 1.99 GHz, windows 7 64bits 8GB Ram, Labview 2015 SP1 (32 bits), VIsion Adquisition Software 2015, Module Vision 2015, DSC 2015, ni OPC Server, Run Time Engine 2015, VIsion Run Time 2015. PC 3 (deployment PC) intel Atom CPU N2600 1.40GHz, windows 7 64bits, 4GB Ram, Labview 2015 SP1 (32 bits), VIsion Adquisition Software 2015, Module VIsion 2015, DSC 2015, ni OPC Server, Run Time Engine 2015, VIsion Run Time 2015. I use the next in my aplication: 2 cameras GigE Lan connected to PC. A PLC connected RS232 through ni OPC server and about 15 shared variables. In development environment my application works well. In PC 2 a executable of my application works well. But the problem is that the same executable works bad in PC 3. Front Panel is slow and displays of image cameras don't refresh the image well. So all my application is slow in PC 3. What can it be? I don't think that it could be the specification of PC 3 but I don't know... Does anyone fix something similar? Any help will be appreciate it. Thanks a lot.
  14. Hi to all. I would like to create an application where usar can train an OCR programmatically. So do the same that vission assistant when user trains OCR but in an application. So, take picture from a camera (I have already done this) then click button, select area to train and put the train (for example type "9" if the image is a number 9). And save it. And if for any reason PC is shutting down, application can remember the train. That is possible?' Thanks a lot!
  15. Hello to all. I would like to know hoe can open my VI with the same configuration. I mean with every indicators, controls, graphs... are equal than when Labview was closed the las time. Is it that possible? I am asking this because I am developing a vision application with vision and motion toolkit. And a ROI is changed every time when I run again Labview in the same position of display. Thanks a lot.
  16. Hello to all. Thanks a lot for reading this post and being able to help. I would like to know what is the most recent release of modbus library for Labview. Which version? 1.1.5.39 of this link http://forums.ni.com/t5/NI-Labs-Toolkits/LabVIEW-Modbus-API/ta-p/3524019 or 1.2.1 of this link http://www.ni.com/example/29756/en/ ? Thanks a lot!
  17. World first 3rd party product supports LabVIEW FPGA from MangoTree Tech NI's RIO series products can be replaced now! Detailed info, please visit http://en.mangotree.cn/ application requirements instead of Compact-RIO.We can give you the performance you want! The flexibility you want! seamlessly,it also support all NI C series module. It combines Intel CPU with Xilinx FPGA: Up to 2.58GHz Intel Dual-core Celeron Processor 64GB SSD 、4GB DDR RAM USB3.0、USB2.0 、Gigabit Ethernet and HDMI interface Spartan6 LX75 FPGA(Optional LX150) Support Windows、WES7 and Pharlap RT OS; PCIe DMA Support all NI C series module
  18. This is an updated posting to the previous posting to reflect changes to the job description and requirements. LabVIEW job opportunity About the company: High tech manufacturing company of non-destructive test equipment and machinery. Small but dynamic business where all employees are able to contribute directly to our success. About the role: Full time on site position developing LabVIEW software products. This candidate will be in charge of software development and hardware integration. Candidate will be responsible for replacing old text based projects into LabVIEW and maintaining existing application. Additional projects are the re-architecting of existing applications to have a more “modern” look and feel. Experience: 3-5 years of LabVIEW application development. FPGA, digital signal processing, database and IT experience a plus, but not necessary. Engineering or physics degree a plus. US Citizenship required. Salary negotiable and commensurate upon abilities. Send resumes and cover letters to resumes@digitalwavecorp.com.
  19. Hello I am trying to program my sumo ev3 robot , and i have a small problem . I am programming the ultrasonic sensor to read distance if it sees someone it attack them and so on . So when it is not seeing an enemy it should rotate a bit to the right a bit to the left but during that rotation i want the robot to detect the enemy and locate them however the robot is actually doing the whole sequence and even it it sees the enemy it doesnt go to the true statement unless it was the very end of the sequence when it detected the enemy . Thank You Best Regards
  20. Hello Everyone, Im pretty new to TestStand, and have to modify a pretty extensive sequence, mainly, we only want to add a step at the end that will retrieve some information from preovius steps and put them in a txt file, this will be done easy using a step to cal a VI, the issue is that i cant retrieve the values i need. This is my MainSequence, this is where the UUT is being tested, i will only focus on 1 value, i want the result value from the 340nm Position Check step: This is my "TestReport" Sequence, it will run after the main sequence, i want to retrieve information in the GetTestResult VI, It seems that i cant get the right context or values, This is the main prototype of my VI I have tried using in step settings, the Context "in" as "RunState.SequenceFile.Data.Seq["MainSequence"]." and then in the lookup string tryied using "Main["340nm position check"].Trans_Red.Result" but it returned an empty string, it should be returning a string like "6.83458985222004". am i doing something wrong?, im attaching the seq file as reference, but not the VI. Thank you so much for your help. Edit1: clean up blank lines in the text. Sequence_Reflectometer_ModifiedForMES.seq
  21. We recorded all JKI presentations and have made them available online. AI and deep learning with Javier Ruiz & Ian McFarlane, .NET integration and interface design with Sarah Zalusky, and Caraya unit testing with Jim Kring. Good stuff! Caraya: A New Take on LabVIEW Unit Testing - TS9754 by Jim Kring Designing a LabVIEW Interface for .NET Applications - TS9757 by Sarah Zalusky Artificial Intelligence With LabVIEW: Deep Learning-Based Classification and Control - TS9758 by Javier Ruiz & Ian McFarlane Watch videos
  22. Background: Precision Acoustics Ltd have been at the forefront of the design, development and manufacture of ultrasonic measurement equipment for over 25 years. The company specialises in the research and development of ultrasonic test equipment used extensively in the QA of medical devices, to provide industry with ultrasonic Non Destructive Examination (NDE) and within academia and national measurement institutes throughout the world. Brief: Together with the Bournemouth University we are looking for a Software Engineer to work on a joint project focused on the development of a new software platform (and associated output) to control acoustic and ultrasound measurement instrumentation. For the successful candidate, this is an exciting opportunity to develop the skills required to plan, manage and execute a significant development project, working alongside and learning from industry experts in LabVIEW development and Agile software development. There is also a significant personal development budget available along with the opportunity to undertake a project-focused Masters in Research (MRes) at the University. Whilst the majority of KTP candidates remain with the industrial partner after the project, the skills acquired would be widely applicable and highly desirable in future employment opportunities. The project will seek to develop a platform and agile development process that has the hallmarks of a well-engineered software system, including all documentation and verification outputs. The solution will ideally integrate existing software developed by the company from internal development, balancing the need for re-use against the need for a best-practice architecture. This must be undertaken in a way that supports the short, medium and long term business operations of the company. For more information and application process visit the Bournemouth university website: https://www1.bournemouth.ac.uk/software-engineer-ktp-associate-fixed-term
  23. Hello I tried to create a LED latch and was successful in doing so. However this LED latch doe not reset itself when I terminate the loop. Does anyone know how to create an led latch with the option of clearing it at the termination of the loop? I have attached my LED latch. Regards Shravan
  24. NI week 2016 is around the corner and this another reason I am excited to attend this year. NI announced the finalist for the LabVIEW Tools Network Product of the year and DQMH made the list. Check out the list of finalists here: https://decibel.ni.com/content/groups/labview-add-on-dev-center/blog/2016/06/20/announcing-2016-award-finalists-and-25-year-honorees See you at NI Week 2016 Fab
  25. Dear all, I am trying to test the remote panel with web server on LV2015 but it always shows "Server does not support Remote Panel". I have already researched some similar topic but still can not find out the solution for my situation. Now I will show the software system as well as my procedure to make my project. First is the system: Now I shows my steps And this is the disappointed result I am doing the thesis with this. so I need your help urgently :'( Thank you in advance
×
×
  • Create New...

Important Information

By using this site, you agree to our Terms of Use.