-
Posts
161 -
Joined
-
Last visited
-
Days Won
10
Content Type
Profiles
Forums
Downloads
Gallery
Everything posted by jacobson
-
I don't think it's always better to use the FPGA over DAQmx. I think the FPGA can be very useful if you need to do some sort of inline processing/scaling, some custom triggering scheme, or if you want to do some closed loop control completely outside of the CPU, but if you're just going to be constantly streaming data to file (basically a headless data logger) then DAQmx would be my choice. One way of looking at it is if your FPGA code is just going to be a passthrough then you probably should just be using DAQmx. For the communication scheme, we would need to know more about how you're going to be interacting with the cRIO. That said, I would probably avoid having the cRIO act as a Modbus slave unless your host application is the master for other Modbus slave devices and you want to treat the cRIO the same as your other slave devices.
-
Windows system GDI object limit problem
jacobson replied to xiongxinwei's topic in Application Design & Architecture
When I had a customer run into this problem they would have a DAbort "Couldn't create 24 pen" in drawmgr.cpp and before that were a ton of "GetDC failed in ISetGPort" DWarns coming from image.cpp (like 15+ DWarns in the 2 seconds before the crash, some within milliseconds of each other). -
We've done Sunday meet ups at Banger's before, I'd be up for that again (lots of outside seating).
-
Including solicitation of interest from potential acquirers
jacobson replied to gleichman's topic in LAVA Lounge
I guess that rules out MATLAB too. -
My first thought would be why even think about building your own solution if you haven't explored the existing alternatives. I only did some minor tests with Francois' API but the client seemed to work well in both Windows and Linux so if you built your own API and posted it to LAVA the first question I would probably ask is why I would want to choose your API over the one I already was using. I think you have to spend some time evaluating existing APIs so you can have a set of reasons as to why you're building yet another API. Even if you have reasons for not liking an existing API it might still be a good use of time to see if you can address those issues by working from the existing API. As an example, if you find that the performance isn't good enough in pure LabVIEW you might not need to start from scratch. If you can get a big performance boost by replacing a few key internal VIs with DLL calls maybe you can bring that to the owner of the existing API and see if that's a change they would make. If they're unwilling to make those changes (maybe they find value in keeping everything in pure LabVIEW) then you can start working on your own API with very clear reasons as to why someone would even want to use it.
-
On the FPGA side, reading 2 U32s or 8 U8s shouldn't make a difference from a throughput sense. Some old info I found internally basically said that if they don't have the same throughput it's a bug. I also don't think the DMA throughput should be effected. If I remember correctly, the DMA engine will try to send multiple data items up at the same time to minimize the overhead of PCIe packet headers.
-
Including solicitation of interest from potential acquirers
jacobson replied to gleichman's topic in LAVA Lounge
I mean stock perfectly reflect the underlying value of the company right? It seems like $53 is a premium my any measurement but they do conveniently hide that when they offered $48 per share it was below the 12-month price target for NATI (pretty sure I have my timelines right). -
Including solicitation of interest from potential acquirers
jacobson replied to gleichman's topic in LAVA Lounge
https://www.emerson.com/en-us/news/2023/emerson-national-instruments-announcement Although all of this is through the lens of the group that wants to purchase NI so it's not surprising they don't think NI is being reasonable (though that may be true). -
What determines which monitor a dialog shows on?
jacobson replied to drjdpowell's topic in User Interface
So when you start your "Modal" VI you'll just set the FP.Behavior to Modal and set it back to Default when the VI finishes executing? I never thought of doing that but seems worth doing it to prevent ready to run modal windows forcing me kill LabVIEW. -
I've seen a few RT applications that use move blocks over type casting as well. Obviously not very safe but it is fast.
-
Software is being modified by both NI and third-party so I think it would be safe to assume that LabVIEW is included under the umbrella of "NI software".
-
In past years there was often a meetup at some random bar on the Sunday night before NIWeek to get some drinks and hang out. Anyone know if there are similar plans in motion this year? If not, does anyone want to meet up somewhere Sunday night?
-
Colours that work together Pantone 2022 colours
jacobson replied to FixedWire's topic in User Interface
If you're working for a larger customer they also might have brand guidelines that you can follow. A long time ago I worked with someone from UT Austin and just followed their published branding material. https://brand.utexas.edu/identity/color/ -
Alternatives to NI-9208 or DAQ competitors?
jacobson replied to HorseBattery_StapleGuy's topic in Hardware
For more general data acquisition systems I'll hear about UEI, VTI, Dewetron, and HBM. Beckhoff comes up plenty but the remote I/O or industrial control space does lead to them having different strengths/weaknesses. -
The question below that seems to indicate that there may not be a call for presentations because they'll just pull from previously accepted sessions but who knows. Hopefully there will be good technical presentations still.
-
I am taking a sabbatical from LabVIEW and NI R&D
jacobson replied to Aristos Queue's topic in LAVA Lounge
The two times we had people in our AE team do this we never got them back 🙃 -
As an NI employee am I part of the legion of doom in this analogy?
-
VSCode's October update changed it so directional formatting characters are displayed by default. https://code.visualstudio.com/updates/v1_62 GitHub also added a warning if you are looking at a file with these characters so hopefully more IDEs are being updated to make this vulnerability more obvious.
-
Pyhton or C to do For Daq and DSP?
jacobson replied to Mahbod Morshedi's topic in Calling External Code
I would generally suggest just using the language you're most comfortable with. I think Python is generally easier to integrate with but you are limited in data types (no classes). If you're just doing some signal processing though that may be able to develop an interface around that limitation without much difficulty. I also don't think LabVIEW supports the ability to call Python from a specific virtual environment which is definitely annoying. I think the C/C++ integration is a little less straightforward than Python but if you're comfortable with the language and you read the help documentation on the Call Library Function Node and how LabVIEW stores data in memory it's not that bad. You may also have to mess with some LabVIEW memory management functions which can be annoying the first time you use them. -
How to embed the NI Vision Acquisition Software in a LabVIEW GUI?
jacobson replied to Ben_V's topic in LabVIEW General
Are you talking about VBAI? I thought Vision Acquisition Software is just the different IMAQ camera drivers so I'm not sure exactly what you're looking to embed from the drivers. -
You are correct that phone/email support is now being handled by a separate Technical Support Engineering (TSE) team which is now a career position (meaning they have senior/principal level engineers working in the department). As examples, you now have folks like Darren N and Norm K working as TSEs. This is still a relatively new change (2 years?) so there are still a lot of newer engineers but I think things are moving in the right direction with hiring very experienced engineers and being able to keep engineers within the department rather than constant attrition to other areas within NI. I know a few people in that group who started there out of college and are still there 5+ years later which definitely would not have happened previously.
-
You can always try calling in on a new case or transfer to a different technical support engineer (I know if used to give you this option if someone wasn't picking up). You don't have to ask them the same question but they should be able to tell you what's going on at least (someone's OOO, case is in some bad state, or more often than not both people think they're waiting for information from the other).
-
What's the case number?
-
I have two 9074 cRIOs I use as bookends at work and even a couple of books I got from stuff people were trying to get rid of. Most of the hardware I would be able to take home is old enough that I don't really want it (I'm not into home automation or maker stuff so I really don't care about old tech).
-
Even though we know we will never go to the True case, I doubt LabVIEW would ever be able to determine that and properly remove dead code. It would require LabVIEW to know that the timestamp output of a primitive converted to a double will never be less than 0. If you wire a false constant into the case selector the VI won't lock up so it does work in that instance. I remember running into issues with events being queued when the VI is only reserved to run by (accidently) embedding VIs that weren't running into subpanels. The VI isn't running but clicking anything can still enqueue events and cause everything to lock up.