Jump to content

Search the Community

Showing results for tags 'visa'.

  • Search By Tags

    Type tags separated by commas.
  • Search By Author

Content Type


Forums

  • Software & Hardware Discussions
    • LabVIEW Community Edition
    • LabVIEW General
    • LabVIEW (By Category)
    • Hardware
  • Resources
    • LabVIEW Getting Started
    • GCentral
    • Code Repository (Certified)
    • LAVA Code on LabVIEW Tools Network
    • Code In-Development
    • OpenG
  • Community
    • LAVA Lounge
    • LabVIEW Feedback for NI
    • LabVIEW Ecosystem
  • LAVA Site Related
    • Site Feedback & Support
    • Wiki Help

Categories

  • *Uncertified*
  • LabVIEW Tools Network Certified
  • LabVIEW API
    • VI Scripting
    • JKI Right-Click Framework Plugins
    • Quick Drop Plugins
    • XNodes
  • General
  • User Interface
    • X-Controls
  • LabVIEW IDE
    • Custom Probes
  • LabVIEW OOP
  • Database & File IO
  • Machine Vision & Imaging
  • Remote Control, Monitoring and the Internet
  • Hardware

Find results in...

Find results that contain...


Date Created

  • Start

    End


Last Updated

  • Start

    End


Filter by number of...

Joined

  • Start

    End


Group


Personal Website


Company Website


Twitter Name


LinkedIn Profile


Facebook Page


Location


Interests

Found 19 results

  1. Hi, I'm connecting to a Rigol DZ1000 Oscilloscope via USB and using the :DISP:DATA? ON,0,PNG command to grab a screenshot. Reading out the data in blocks of 65535 bytes until there is no more (see attached vi). This normally works fine but yesterday I was getting a timeout error. I fired up IO Trace and got this: > 783. viRead (USB0::0x1AB1::0x04CE::DS1ZA201305475::INSTR (0x00000001), "#9000045852‰PNG.......", 65536 (0x10000), 45864 (0xB328)) > Process ID: 0x000039C8 Thread ID: 0x00001760 > Start Time: 13:13:54.1169 Call Duration 00:00:10.4323 > Status:
  2. I am experiencing numerous VISA Lock Errors (-1073807345) on resources I haven't explicitly locked. This is happening on TCPIP connections to keysight N6700 power supplies and keysight N5242 PNA fairly regularly. I have simultaneous loops in the application communicating to the different instruments, using a sequencer of sorts to pipe commands one at a time to each of my various loops. Has anyone seen the locking error pop before while not actually using the Lock and Unlock VIs? This issue has gotten worse lately and it has come time to find the root cause. My only thoughts are th
  3. Hey guys, Can you take a look at this? The only work around I found is to dynamically open the connection with an external VI to make it fail so the second time it works. If anyone has an instrument that communicate trough TCP-IP with VI, please try on your side with LabVIEW 2018 and visa 18. https://forums.ni.com/t5/LabVIEW/VISA-error-with-TCP-IP-BK-precision-2190E/m-p/3876316 Thanks
  4. I wanted to cross post metux's discovery here asap, and have a separate discussion. Metux's original post: The recent Linux driver package introduces a CRITICAL security vulnerability: http://www.ni.com/download/ni-linux-device-drivers-2018/7664/en/ It adds additional yum/zypper repos, but explicitly disabling package signing and using unencrypted HTTP transport. That way, it's pretty trivial to completely takeover the affected systems, by injecting malicious packages. DO NOT INSTALL THIS BROKEN SOFTWARE - IT IS DANGEROUS ! CERT
  5. hi, I need to make an application , which has to send a hexa decimal data from labview to the protocol via RS232.I have sent a single data block(1Byte) and i was able to receive the acknowledgement properly. But if i send a 9 bytes of Data through VISA via RS232, I am not getting any output at all , But if I send the same data block through different application, I am able to receive data . Can anyone suggest me way to resolve the issue or Better way to do this?? I have attached my vI with this . I am struggling at this point for so long. POC.
  6. Hi We have an application where we need to have a custom PCIe board transfer data to the PC using DMA. We are able to get this to work using NI-VISA Driver Wizard for PXI/PCI board. The recommended approach is to have VISA allocate memory on the host (PC) and have the PCIe board write to it (as seen below). While this approach works well, the memory allocated by VISA for this task is quite limited (~ around 1-2MB) and we would like to expand this to tens of MB. Note: The documentation (and help available on the web) regarding these advanced VISA function (for inst
  7. Version 1.0.0.0

    248 downloads

    This VI list all VISA session opened and allow you to close all of them. Some times when the GPIB stuck and the VI wont stop..... This VI is a better solution than reboot.
  8. Name: List all VISA session opened Submitter: Benoit Submitted: 30 Jan 2016 Category: *Uncertified* LabVIEW Version: 2011License Type: BSD (Most common) This VI list all VISA session opened and allow you to close all of them. Some times when the GPIB stuck and the VI wont stop..... This VI is a better solution than reboot. Click here to download this file
  9. Hello. I have a mesytec mscf-16 module and i want to control it using labview via usb. Using hyperterminal i can communicate with the module and send commands so the ftdi driver works fine. The problem is that i can't control the module using labiview. Using ni-max test panel if i send idn? command i receive idn? as response and the same happens with every other string. Any information on this subject is appreciated since i am new in programming and i don;t know my way around labview. Thx
  10. piZviZ

    Visa Read

    In my project i have 2 task (1).Read data of sensor (attached to arduino board) serially and display on LabVIEW. (2).Control output(just ON-OFF) pins of arduino using LabVIEW. So,for that i am using TAB in labview.created 2 TAB called Oscillospe and Input. If i first start Oscilloscope it work well. But when i come to Oscilloscope tab after using Input tab. It gives Time out error (VISA read) If i am executing in Highlight mode it works well tab--event.vi
  11. Hi everyone, so we have a device for measurement & signal generation and want to make it accessible through VISA say by Ethernet / USB / Serial. Other than the VISA driver template and the SCPI parser that must be implemented on the device, does anyone offer a good starting point on how to make a device talk VISA and maybe even get it certified by NI? Thanks in advance
  12. Hi, I have several USB instruments (Agilent/Keysight optical power meters) which I can talk to via USB. To minimise the time "wasted" by transferring data between the instruments and the PC I would like to query them in parallel. Unfortunately, LabVIEW doesn't agree with that strategy and reliably crashes when doing so. It doesn't matter which command I send, so here's a sample snippet, where I just query the instrument ID repeatedly. I don't even have to read the answer back (doing so won't make a difference): This will kill LabVIEW 2012 and 2014, both 64bit without even popping up th
  13. I am working on an RT app and hardware that uses more than 50 USB devices connected via USB hubs to an NI rackmount computer. After a hard reboot of the rack mount computer, the USB devices and hubs take more than 5 minutes to enumerate. I am looking for a way to verify all the USB devices have enumerated. Polling VISA Find Resources appears to cause the entire system to lockup if we start it immediately in RT app. If we manually delay for 10 minutes or so in the application and then call VISA Find Resources, it appears to work OK as long as all of the devices have successfully enumer
  14. Hi everyone, New on this site, new to Labview, new to RS232 and actually new to pretty much everything! Hope I'm not posting in the wrong section... I feel a bit out of place anyway to be posting among experts but well, for lack of a better place... So here's the context of my problems : I'm trying to set up a (crude) acquisition system based on an arduino and a couple of multiplexers / Thermocouple conditionners. My arduino is sending via its own USB-RS232 converter a string of all the values (approx. 20) as characters. I figured out I could use Labview to do a nice display
  15. I'm running a queue controlled multi-loop many master/many slave data parser (among other features), and gosh darn it if it isn't mostly working! However, one issue that I'm running into is an extremely un-reproducible error in the serial data read/write loop out to a USB Telegesis module. I can't seem to replicate it, and when it happens, it may happen a few times in a row, but usually upon a software reset, disappears again. This software will be running for a significant period of time without user intervention, so I can't afford to have this happen when someone's not around to fix it.
  16. Hi All, This is my first post on LAVA, so here it goes: I am creating an application that involves reading data on two RS-422 serial ports. Everything was going just dandy until it was time to build my application into an executable. I've spent time debugging my issue and have been able to narror down where the source of the error is coming from, but I can't figure out why it's happening or how to fixt it. I created a simple VI that clearly demonstrates the error. The VI first configures two serial ports using VISA. It then gets the number of bytes at the port and reads from VISA
  17. Kello everyone! I have some instruments which i controll over VISA. the software has two parts: one GUI running on a computer and the program running on the PXI to which the instruments are connected. I would like the user to be able to choose the GPIB address of each instrument on the GUI, so i created a cluster of GPIB controls. My problem is that while the same cluster on the software of the PXI gives the posible addresses from the instruments connected to it, on the GUI it does not. One easy solution is the user to write the number of each instrument and manipulate the string but i
  18. My machine have to send a sequence of 3 bytes per command via serial port. for example; |start byte=0xFF| |second byte = 0x00-0xFE| | third byte = 0x00-0xFE | which I have already done with it, my method is sending one byte per one byte in for-loop via serial port. The problem is if I would like to control more machines my VI will going to be more complicate and that is very bad.. Can LabVIEW able to send my 3 bytes protocol above with just one-time sending?? for example: like in C-language, I'm gonna use printf ("%c %c %c",start,second,third); I'm new with LabVIEW any idea please hel
  19. Hi there, This is my first posting on lava. A coworker pointed me here after I told him I had reached my limit trying to debug this hardware issue. I have a PMC device I am trying to test. The test plan calls for putting 2 of the devices on PMC-PCI adapter cards and installing them in a Windows PC, then running tests. When I put just one of the devices in the PC I didn't have a problem. I made a driver using NI's VISA driver wizard. And I was able to read from the PCI configuration and BAR0 address spaces of the device using the VISA test panel in MAX. However, when I plugged in the second D
×
×